![background image](http://html1.mh-extra.com/html/omron/zfv-series/zfv-series_user-manual_744103065.webp)
62
Section 3
SETUP
ZFV
User’s Manual
Section 3
Changing the Input/output Conditions
■
Selecting one-shot output ON/OFF
Set whether or not to enable one-shot output on the OUTPUT signal.
MENU Mode-[SYS2]-[OUTPUT]-[ONE SHOT]
■
Setting the one-shot output time
OUTPUT turns ON for the preset time from when the OUTPUT signal turns ON.
This setting is valid only when [ONE SHOT] is set to [ON].
MENU Mode-[SYS2]-[OUTPUT]-[OUTPUT TIME]
Setting the ON delay time
Set this item to delay the timing that the OUTPUT signal turns ON.
MENU Mode-[SYS2]-[OUTPUT]-[ON DELAY]
Setting
Description
OFF (default value)
One-shot output is not performed.
ON
One-shot output is performed.
Setting
Description
0 to 255 (default value:0)
Set the time (ms) that OUTPUT is turned ON.
Setting
Description
0 to 255 (default value:0)
Set the time (ms) to delay turning ON of the OUTPUT signal.
When one-shot output is set to [ON], the OFF delay time setting is disabled.
OFF
ON
OUTPUT
Delay time
OUTPUT ON at OK judgment in continuous measurement
Judged as NG
Judged as OK
Judged as NG