![Omron YSC-8361 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/omron/ysc-8361/ysc-8361_instruction-manual_1633449009.webp)
9
7.6
Disable the safety switch
If you want to disable the function of Safe SW., you can change the value of
“
O31
” from “1” to “0” normally, in a particular case, for example, the Safe SW. broke
down, you can power on while press “
C+
” key to disable the function of Safe SW.
warning
:
it means potential security problems for you if you
disable
the function of Safe
SW., so attention please.
7.7
Parameter list
SN
PARAMETER
RANGE
DESCRIPTION
S Type Para
S01
Max Speed
500
~
3000spm
Unit: stitch/min
S02
Min Speed
150
~
500spm
Unit: stitch/min
S03
Start tacking speed
500
~
2000spm
Speed adjustment for
start tacking
S04
End tacking speed
500
~
2000spm
Speed adjustment for end
tacking
S05
Bar-tacking speed
500
~
2000spm
Speed adjustment for
bar-Tacking
S06
C-S sewing speed
500
~
2000spm
Speed
adjustment
for
constant-stitch sewing
S07
Trimming speed
150
~
300spm
Speed adjustment for
trimming
S08
Soft start speed
200
~
500spm
Soft start speed
S09
Speed limit for stroke
height level 1
500
~
4000spm
S10
Speed limit for stroke
height level 2
500
~
4000spm
S11
Speed limit for stroke
height level 3
5004
~
000spm
S12
Speed limit for stroke
height level 4
500
~
4000spm
T Type Para
T01
RVS action time
1
~
200
(
ms
)
Action time of the REV
SOL.
T02
RVS release time
1
~
200
(
ms
)
Release time of the REV
SOL.
T05
Foot lifter delay time
setting
1
~
500
(
ms
)
Foot lifter Delay time
adjustment for pedal’s
feet lift position
T06
Running-Delay
time
setting
1
~
500
(
ms
)
Running
delay
time
adjustment for Automatic
Foot Lifter