8
6.6
Lower thread counter
SN F6
:
display how much the lower thread is remaining
7.
PARAMETER
I
NSTRUCTION
7.1
Setting parameter
Press
to enter the parameter Interface.
Display E shows the parameter type, press “
E+
” and “
E-
“ key to change it.
Display F, G show the parameter index, press “
F+
”
,
“
F-
“, “
G+
”
,
“
G-
“
key to change it.
Displays A, B, C, D show the parameter value, press the keys under them to change it.
For example, figure 4
:
parameter index is 1, type is P, value of “S01” is 2000, the nixie
tube will blink when change the value. Press
to confirm, press
to cancel
and return to sewing interface.
figure 4: the parameter interface
7.2
Get the permission of setting o type parameter
Only S, T and A type parameter can be select normally, if you want to change
the O type parameter, you must press
key when switching power on,
when panel shows
『
DO EN
』
, you get the permission successfully.
7.3
Parameter solidifying
If the operator want to change some parameter’s default value, then select the
parameter, press
maintain a moment, after
『
SD OK
』
displaying, the
default value has been changed.
7.4
Resumine parameter through one-key default
Select any parameter in parameter interface,
can be used to recall the
default value. The display will be twinkling if the parameter is modified, use
to confirm or
to cancel the change
7.5
Controller recovery
Resume the default value of all parameters
Set parameter
O17
to “ON”, turn on the power again, after twinkling of
“INIT” finished, all parameters have been default value themselves
Restore Factory Defaults
Set parameter
O51
to “ON”, turn on the power again.