background image

 

6.6

 

Lower thread counter 

SN F6

display how much the lower thread is remaining 

7.

 

PARAMETER 

I

NSTRUCTION 

7.1

 

Setting parameter 

Press 

  to enter the parameter Interface. 

Display E shows the parameter type, press “

E+

” and “

E-

“ key to change it. 

Display F, G show the parameter index, press “

F+

,

 “

F-

“, “

G+

G-

 

key to change it. 

Displays A, B, C, D show the parameter value, press the keys under them to change it. 

For example, figure 4

parameter index is 1, type is P, value of “S01” is 2000, the nixie 

tube will blink when change the value. Press 

  to confirm, press 

  to cancel 

and return to sewing interface. 

 

figure 4: the parameter interface

 

7.2

 

Get the permission of setting o type parameter 

Only S, T and A type parameter can be select normally,    if you want to change 

the O type parameter,    you must press 

  key when switching power on, 

when panel shows

DO EN

, you get the permission successfully.

 

7.3

 

Parameter solidifying 

If the operator want to change some parameter’s default value, then select the 

parameter, press 

  maintain a moment, after 

SD OK

  displaying, the 

default value has been changed. 

7.4

 

Resumine parameter through one-key default 

Select any parameter in parameter interface, 

  can be used to recall the 

default  value.  The  display  will  be  twinkling  if  the  parameter  is  modified,  use 

 

to confirm or 

 

to cancel the change

 

7.5

 

Controller recovery 

 

Resume the default value of all parameters 

Set  parameter 

O17

  to  “ON”,  turn  on  the  power  again,  after  twinkling  of 

“INIT” finished, all parameters have been default value themselves

 

 

Restore Factory Defaults 

Set parameter 

O51

 to “ON”, turn on the power again. 

Содержание YSC-8361

Страница 1: ...1 INSTRUCTION MANUAL YSC 8361 AC Servo System Please read the manual before using the Controller Please keep the manual for easy reference Version V 002beta 20160615...

Страница 2: ...is 5 45 and humidity is 80 or less 1 2 Notice of installation Turn off the power and unplug the cord before installation The cables must not set to be near the wheel and other movable parts To avoid...

Страница 3: ...are both in range 1 15 Double start tacking A is the stitches of forward sewing B is the stitches of backward sewing They are both in range 1 15 End tacking Single end tacking C is the stitches of ba...

Страница 4: ...g will be done automatically The pedal must be returned to balance for next sewing Lower thread Counter Enter lower thread counter interface Soft start Enable or disable the soft start Needle Up Needl...

Страница 5: ...to 6 6 Initial counter Press the initial value of the lower thread counter which was set previously will be shown Adjust it to a suitable value How the counter works Display initial value The counter...

Страница 6: ...unctions on the keypad Figure 2 Keypad on the machine arm Foot stroke Toggle foot stroke level Start and end strips This key cancels the general setting for sewing start and end strips If strips are a...

Страница 7: ...switch THIS IS ACUSTOMIZABLE HOT KEY Default Pressing the key changes the sewing direction Refer to Parameter list A04 6 OPERATION OFTHE SPECIAL FUNCTION INTERFACE Press switch to the special functio...

Страница 8: ...rameter can be select normally if you want to change the O type parameter you must press key when switching power on when panel shows DO EN you get the permission successfully 7 3 Parameter solidifyin...

Страница 9: ...adjustment for end tacking S05 Bar tacking speed 500 2000spm Speed adjustment for bar Tacking S06 C S sewing speed 500 2000spm Speed adjustment for constant stitch sewing S07 Trimming speed 150 300spm...

Страница 10: ...erse switch function 0 12 You can choose between 0 none 1 reverse 2 half stitch correction 3 continuously correction 4 half stitch correction at machine stop reverse at machine run 5 continuously corr...

Страница 11: ...fer to O35 1 On 0 Off A14 0 1 Automatic Foot Lifter at stop 1 On 0 Off A15 0 1 Automatic Foot Lifter after trimming 1 On 0 Off A16 0 1 Automatic constant stitch sewing after start tacking only when A0...

Страница 12: ...angle of Reverse SOL D06 0 359 Switch off angle of Reverse SOL D07 0 359 Switch on angle of thread clamp SOL D08 0 359 Switch off angle of thread clamp SOL D13 0 359 Switch on angle of thread tension...

Страница 13: ...topped 0 Can not Correct after trimming O72 0 10 torque enhancement function when running at low speed 0 Off 1 10 level 1 10 O84 0 720 Step width for electronic hand wheel O85 0 200 Speed for electron...

Страница 14: ...ine Replace the encoder Replace the motor E110 Encoder Synchronizer fault check or replace the synchronizer for a belt drive machine check or replace the encoder for a direct drive machine E190 E290 S...

Страница 15: ...EFG Encoder 1 8 Speed Limit Device to stroke DigitalType AnalogType 1 9 AC voltage 1 10 Bus voltage 1 11SoftwareVersion 1 12HardwareVersion 1 13Software Release Date 2 Appendix 2 1 Machine ID 2 1 1 Ho...

Страница 16: ...16 2 2 Seven Segment DisplayCharacters CompareTable 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z...