background image

XW6T

5

Standards

Compliant standard

• UL1059
• CSA (C22.2 No.158)
• IEC 60947-7-1

Certification

• cURus (File No. E245101)

Dimensions

(Unit: mm)

Model

Accessories (Order separately)

(For addition) Terminal Block

25.3

78

31.3

A

XW6T-COM1.5X

@@@@

Dimension A

Model

Number of pins

Dimensions

XW6T-COM1.5X8

@@

8 pins

9.2

XW6T-COM1.5X12

@@

12 pins

12.7

XW6T-COM1.5X16

@@

16 pins

16.2

XW6T-COM1.5X20

@@

20 pins

19.7

XW6T-COM1.5X40

@@

40 pins

37.2

A

30.1

82.6

36.1

XW6T-COM2.5X

@@@@

Dimension A

Model

Number of pins

Dimensions

XW6T-COM2.5X8

@@

8 pins

12.6

XW6T-COM2.5X12

@@

12 pins

17.8

XW6T-COM2.5X16

@@

16 pins

23.0

XW6T-COM2.5X20

@@

20 pins

28.2

XW6T-COM2.5X40

@@

40 pins

54.2

25.3

78

31.3

3.5

XW6T-COM1.5

30.1

82.6

36.1

5.2

XW6T-COM2.5

Содержание XW6T Series

Страница 1: ...ns 8 8 pins 12 12 pins 16 16 pins 20 20 pins 40 40 pins 1 Maximum Applicable Stranded Wire 1 5 1 5 mm2 2 5 2 5 mm2 3 Color of Short Bars RD Red BL Blue YL Yellow Terminal insertion hole Release hole t...

Страница 2: ...T COM1 5X12RD Blue XW6T COM1 5X12BL Yellow XW6T COM1 5X12YL 16 Red Approx 29 XW6T COM1 5X16RD Blue XW6T COM1 5X16BL Yellow XW6T COM1 5X16YL 20 Red Approx 36 XW6T COM1 5X20RD Blue XW6T COM1 5X20BL Yell...

Страница 3: ...cks Number of poles Covering color Model Application XW6T COM1 5X 2 Red RD Blue BL Yellow YL XW5S P1 5 2 Used for crossover wiring between Terminal Blocks 3 XW5S P1 5 3 4 XW5S P1 5 4 5 XW5S P1 5 5 10...

Страница 4: ...8 16 pins 23 0 20 pins 28 2 40 pins 54 2 IEC rated voltage 500 V 800 V IEC rated current 17 5 A 1 5 mm2 24 A 2 5 mm2 Usage Group UG B C D B C UL rated voltage 300 V 51 to 150 V 151 to 300 V 301 to 60...

Страница 5: ...l Number of pins Dimensions XW6T COM1 5X8 8 pins 9 2 XW6T COM1 5X12 12 pins 12 7 XW6T COM1 5X16 16 pins 16 2 XW6T COM1 5X20 20 pins 19 7 XW6T COM1 5X40 40 pins 37 2 A 30 1 82 6 36 1 XW6T COM2 5X Dimen...

Страница 6: ...XW5S P1 5 2 3 5 XW5S P1 5 3 7 0 XW5S P1 5 4 10 5 XW5S P1 5 5 14 0 XW5S P1 5 10 31 5 XW5S P2 5 Model P mm XW5S P2 5 2 5 2 XW5S P2 5 3 10 4 XW5S P2 5 4 15 6 XW5S P2 5 5 20 8 XW5S P2 5 10 46 8 5 2 23 3 1...

Страница 7: ...mount them so that the conductive parts of the adjacent Terminal Blocks are facing in the same direction If they face in different directions short circuit may occur between adjacent Terminal Blocks D...

Страница 8: ...e release hole Checking Connections When you complete wiring an indicator for the wire insertion state turns to green To prevent short circuits insert the stripped part of a stranded or solid wire or...

Страница 9: ...E 0 75 8N GY 10 12 AI 0 75 10 H0 75 16 FE 0 75 10N GY Recommended crimp tools CRIMPFOX6 CRIMPFOX6T F CRIMPFOX10S PZ6 roto Variocrimp4 Applicable wire Ferrule Conductor length mm Stripping length mm Fe...

Страница 10: ...it up from the Terminal Block 1 operate the screwdriver so that it catches the hook 2 and then remove the Terminal Block with the divided state 3 However do not apply excessive force to the Terminal...

Страница 11: ...nnected to each other Side surface Labels 1 Remove the Labels one at a time 2 Insert them on the sides of the Terminal Blocks Note 1 Different models of Labels are used for the top and side surfaces 2...

Страница 12: ...TERS Chicago IL USA 847 843 7900 800 556 6766 automation omron com Controllers I O Machine Automation Controllers MAC Motion Controllers Programmable Logic Controllers PLC Temperature Controllers Remo...

Отзывы: