41
Precise Defect
Section 3-16
Comparing interval Y 1 to 32 [10]
Set the number of neighboring
elements compared with when
the degree of defect is calcu-
lated, For example, if the sam-
pling interval Y is set to 4 and
the comparing interval Y is set
to 2, comparison is with sepa-
rate elements of 4 x 2 = 8 pixels
along the Y axis.
Direction • X
(circumferential)
• Y (radial)
• Diagonal
Set the direction for detecting
defects.
The smaller the direction setting
count, the shorter the process-
ing time.
Setting item
Set value [Factory default]
Description
Содержание Xpectia-FZ3 Series
Страница 1: ...Xpectia FZ3 Series Vision System SHORT OPERATION MANUAL Cat No Q29E EN 01...
Страница 2: ......
Страница 3: ...Vision System Xpectia FZ3 Series Short Operation Manual...
Страница 4: ......
Страница 10: ...6 Software Overview Section 1 3...
Страница 17: ...13 Processing Item Guideline Section 2 3 2 3 1 Position Compensation...
Страница 18: ...14 Processing Item Guideline Section 2 3 2 3 2 Locating Measurement Objects Not Inclined...
Страница 20: ...16 Processing Item Guideline Section 2 3 2 3 5 Presence Inspection 2 3 6 Dimension Inspection Measurement...
Страница 21: ...17 Processing Item Guideline Section 2 3 2 3 7 Burr Inspection 2 3 8 Text Comparison Inspection...
Страница 24: ...20 Processing Item Guideline Section 2 3...
Страница 34: ...30 Scan Edge Position Section 3 9 3 9 1 Judgment Conditions Scan Edge Position...
Страница 52: ...48 Date Verification Section 3 21...
Страница 54: ...50 Image Logging Section 4 1...
Страница 56: ...52 Data Output Section 5 1...