Problem

Solution with CX-Compolet

Note: When combined with the CJ2 with EtherNet/IP functionality.

Main CX-Compolet Functions

Interface

Function

Description 

Properties

Communications with SYSMAC PLCs

Specifies the PLC to communicate with, and reads network information.

Reading and writing I/O memory 

Operating status

Reads and changes the operating mode.

Area information

Reads information such as the program area size and number of DM Area words.

Error information

Reads the value and error message when an error occurs.

Other SYSMAC PLC information

Reads the model and reads and changes the clock.

Methods

Reading and writing I/O memory 

Creating I/O tables

Creates the I/O tables for the present configuration.

Force-setting, force-resetting and clearing bits

Force-sets, force-resets, and clears bits.

Communications with SYSMAC PLCs

Specifies the PLC to communicate with.

FINS service execution

Sends FINS commands and gets the responses that are received.

Events

Scheduled events

Events occur at regular intervals.

Environment for CX-Compolet 

Item

Description

Languages

English or Japanese

Supported OS

Windows 2000, XP, or Vista 
and 2003 Server

. N E T   F r a m e w o r k  
( 1 . 1 ,   2 . 0 ,   3 . 0 ,   o r   3 . 5 )

Development 
environment

Creating and Modifying VB/VC# Communications Programming Is Too Much Work

Situation

CX-Compolet is a package of software components that make it easy to program reading and writing OMRON PLC data. 

Easily Create Programming to Read and Write PLC Data using VB or VC#. 

.NET Control Objects

ActiveX Control Objects are also included.

SYSMAC Gateway

SYSMAC PLC

NEW

NEW

NEW

CX-Compolet

User-created Applications

VB.NET or VC#.NET 

CX-Compolet

.NET Controls

Example: 
Reading I/O Memory

D0

1234

Simply Paste to a Form and Enter a Line of Code.

3

2

1

4

5

Text1=SYSMAC CJ2.ReadVariable “PV”)

 Software Configuration

 System Configuration Examples

 Application Example

 Procedure

SYSMAC Gateway

SYSMAC PLC

Easily Program Device Alarm Monitoring.

VB.NET/VC#.NET

CX-Compolet

Controller Link

Controller Link

CX-Compolet can access the PLCs in all of the following configurations.

USB

RS-232C

Special Cable

CJ2/CP1

CJ2/CJ1/CS1

USB

CJ2

CJ2/
CJ1/
CS1

EtherNet/IP

CX-Compolet

CX-Compolet

CX-Compolet

RS-232C

CJ2/
CJ1/
CS1

CX-Compolet

CJ2/
CJ1/
CS1

Ethernet

CJ2/
CJ1/
CS1

EtherNet/IP

CX-Compolet

CJ2/
CJ1/
CS1

CJ2/
CJ1/
CS1

CX-Compolet

CJ2/
CJ1/
CS1

EtherNet/IP

Alarm A

Alarm B

6

7

CX-Compolet

CX-Compolet

 Read and write I/O memory in the PLC, change the 

operating mode, read error logs, and perform other 
operations.

 Supports Microsoft Visual Studio.NET 2008.

 Can be used from Visual Basic.NET and 

Visual C#.NET.

 For the CJ2 with EtherNet/IP functionality, I/O 

memory in the PLC can be accessed by using 
tag names rather than addresses.

 Array variable access is possible.

Simply paste to the form and 
specify the tags (addresses).

Example

Press the button to read the 
value (D0 in this example).

Customers who are 
developing VB/VC# programs 
including communications 
with PLCs

Having to program communications 
frame assembly, reception response 
interpretation, and monitoring is too 
much work.

Having to change communications 
processing, e.g., for Ethernet and serial 
communications, is too much work.

Handling PLC address changes is 
particularly time consuming.

For a block of data of the same data 
type, it is too much work to have to 
specify the addresses one by one rather 
than being able to view them as one 
group and access that data as an 
element.

Processing such as communications frame assembly is prepared 
in advance!

Data is accessed by using tag names rather than by using 
addresses, so programming does not have to be changed even if 
PLC addresses are changed.

Array variables are supported, so data can be easily specified by 
simply changing the element subscript with the same tag name.

After installation, the 
OMRON SYSMAC CJ2 
Icon will be displayed in 
the controls.

Position the SYSMAC 
CJ2 Icon in the form.

Arrange the command buttons, 
text boxes, etc., in the form.

Set the remote PLC in 
the properties.

In the Command Button Code 
Dialog Box, enter the PLC tag 
name on one line. (The tag 
name below is “PV.”) 

Commercially 
available USB cable

Data links

Data links

Controller Link 
Support Board

Note: 

The above configurations are only examples. Communications are also possible with PLCs 

other than those shown here. For details, refer to page 8.

 Using the control components provided by CX-Compolet frees the application designers from having to program the communications portions of the 

application.

 Data for device alarms and other data are sent to the applications using non-solicited EtherNet/IP communications events.

 Standardization is made easy by specifying data using tag names (such as “Alarm A” and “Alarm B”) in the applications.

Read and writes data in memory areas, such as the DM Area or CIO 
Area. For example, DM word 100 can be specified by using “D100” 
or by using a tag name.

Reads and writes memory, such as consecutive words in the DM 
Area or CIO Area. For example, it is possible to specify the data type 
(integer, single, etc.) or change the data type (BCD, BIN, SBIN).

Supported 
execution 
environment

Microsoft Visual Studio 
.NET (See note.), .NET 
2003, .NET 2005, or 
.NET2008
Development languages: 
Visual Basic.NET and Visual 
C#.NET
Visual Basic version 5 or 6 
(Only the functions 
compatible with Compolet 
V2 can be used.)

Note:

 Only the components compatible with 

SYSMAC Compolet version 2003 are 
supported. A development environment of 
.NET 2003 or higher is required for CIP 
communications.