24
3
(Operation of the Teaching
pendant)
The same operate to compile
the user task file (USERTASK-
A.990), select the file and
press [Execute].
4
(Operation of the Teaching
pendant)
Press <Service Utilities>,
Select [12 User Task]- [1
User Task] and press [Enter]
on the teaching pendant.
Set the priority number as 5
in [Priority of function].
*Change the operator
qualification to
EXPERT
5
Set the length of TOOL32, it
is used as the flange
coordinate.
(Operation of the Teaching
pendant)
Select [Constant Setting] - [3
Machine Constants] - [1 Tool
Constants].
Align the cursor with the
desired position, input a
number (such as 1), and then
press the [Enter] key.
Set the length x, y, and z as
0.0.
Upon completion of the
settings, press the
[Complete] key.