Degree of Protection
Ingress protection degrees (IP-
@@
) are determined by the following tests. Be sure to check the sealing
capability under the actual operating environment and conditions before actual use.
IEC (International Electrotechnical Commission)
IEC 60529:2001
(A) First Digit: Degree of Protection from Solid Materials
(B) Second Digit: Degree of Protection Against Water
Degree
Protection
0
No protection
1
Protects against penetration of any solid object such as a hand that is 50 mm or more in diameter.
2
Protects against penetration of any solid object, that is 12.5 mm or more in diameter. Even if finger
or other object 12 mm in diameter penetrates, it will not reach a hazardous part.
3
Protects against penetration of any solid object, such as a wire, that is 2.5 mm or more in
diameter.
4
Protects against penetration of any solid object, such as a wire, that is 1 mm or more in diameter.
5
Protects against penetration of dust of a quantity that may cause malfunction or obstruct the safe
operation of the product.
6
Protects against penetration of all dust.
Degree
Protection
Test method (with pure water)
0
No protection
Not protected against water.
No test
1
Protection against water
drops
Protects against vertical drops
of water towards the product.
Water is dropped vertically
towards the product from the
test machine for 10 min.
2
Protection against water
drop
Protects against drops of
water approaching at a
maximum angle of 15
°
to the
left, right, back, and front from
vertical towards the product.
Water is dropped for 25 min
each (i.e., 10 min in total)
towards the product inclined
15
°
to the left, right, back,
and front from the test
machine.
3
Protection against
sprinkled water
Protects against sprinkled
water approaching at a
maximum angle of 60
°
from
vertical towards the product.
Water is sprinkled for 10 min
at a maximum angle of 60
°
to the left and right from
vertical from the test
machine.
50 mm dia.
12.5 mm dia.
2.5 mm
1 mm
200 mm
200 mm
15
°
0.07
l
/min
per hole
Содержание V680S Series
Страница 16: ...14 RFID System User s Manual Modbus TCP Introduction Introduction MEMO ...
Страница 58: ...56 Section 1 Data Characteristics RFID System User s Manual Modbus TCP Section 1 Product Overview MEMO ...
Страница 64: ...62 Section 2 System Configuration RFID System User s Manual Modbus TCP Section 2 System Configuration MEMO ...
Страница 72: ...70 Section 3 Component Names RFID System User s Manual Modbus TCP Section 3 Component Names MEMO ...
Страница 242: ...240 Section 8 Operation Interface RFID System User s Manual Modbus TCP Section 8 Web Browser Interface ...
Страница 337: ...Index 335 RFID System User s Manual Modbus TCP Index ...
Страница 342: ...340 RFID System User s Manual Modbus TCP MEMO ...
Страница 343: ......