GET MULTI-READER/WRITER STATUS
This query reads the Multi-Reader/Writer status.
Query Format
Response Format
Normal Response
Error Response
Reading the Multi-Reader/Writer Status When the Master Reader/Writer Is Ready for Field Extension
Mode and Slave Reader/Writer 1 Was Successfully Connected
TX:000000000006FF03CB000008
RX:000000000013FF031010010001000000000000000000000000
Parameter
Description
Register number
The register address (CB00 hex) that specifies the Multi-Reader/Writer status.
Word count
This is the number of words in the Multi-Reader/Writer status (0008 hex).
Parameter
Description
Byte count
This is the number of bytes in the status of the Multi-Reader/Writer (16 hex).
Multi-Reader/
Writer status
Master status
Contains the status of the Master Reader/Writer in 4-digit hexadecimal.
0000 hex: Disable (default setting)
1000 hex: Preparing for Field Extension Mode (Detecting Groups)
1001 hex: Ready for Field Extension Mode (Group Detection Completed)
2000 hex: Preparing for High-speed Traveling Mode (Detecting Groups)
2000 hex: Ready for High-speed Traveling Mode (Group Detection Completed)
Slave 1 status
Contains the connection status of the Slave Reader/Writers in 4-digit hexadecimal.
0000 hex: Not registered
0001 hex: Connection successful
0002 hex: Connection failed
:
Slave 7 status
Parameter
Description
Exception code
For details, refer to
in this section.
Byte-0
Byte-1
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Byte-7
Byte-8
Byte-9
Byte-10
Byte-11
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function code
Register number
Word count
X
X
0000 hex
0006 hex
FF hex
03 hex
CB00 hex
0008 hex
Byte-0
Byte-1
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Byte-7
Byte-8
Byte-9
…
Byte-24
Transaction
identifier
Protocol
identifier
Field length
Unit
identifier
Function code
Byte count
Multi-Reader/Writer
status
X
X
0000 hex
0013 hex
FF hex
03 hex
10 hex
16 bytes
Byte-9
Byte-10
Byte-11
Byte-12
…
Byte-23
Byte-24
Master status
Slave 1 status
Slave 7 status
2 bytes
2 bytes
2 bytes
Byte-0
Byte-1
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Byte-7
Byte-8
Transaction
identifier
Protocol identifier
Field length
Unit
identifier
Function code
Exception
code
X
X
0000 hex
0003 hex
FF hex
83 hex
1 byte
Содержание V680S Series
Страница 16: ...14 RFID System User s Manual Modbus TCP Introduction Introduction MEMO ...
Страница 58: ...56 Section 1 Data Characteristics RFID System User s Manual Modbus TCP Section 1 Product Overview MEMO ...
Страница 64: ...62 Section 2 System Configuration RFID System User s Manual Modbus TCP Section 2 System Configuration MEMO ...
Страница 72: ...70 Section 3 Component Names RFID System User s Manual Modbus TCP Section 3 Component Names MEMO ...
Страница 242: ...240 Section 8 Operation Interface RFID System User s Manual Modbus TCP Section 8 Web Browser Interface ...
Страница 337: ...Index 335 RFID System User s Manual Modbus TCP Index ...
Страница 342: ...340 RFID System User s Manual Modbus TCP MEMO ...
Страница 343: ......