background image

Precautions for Safe Use

 

Be sure to observe the following precautions to ensure safe use of the Products. 

1. Do not use the Products in environments with flammable, explosive, or corrosive gasses. 

2. Do not attempt to disassemble, repair, or modify any Product. 

3. Tighten mounting screws securely. 

4. If any cable has a locking mechanism, make sure that it has been locked before using the cable. 

5. Do not allow water or pieces of wire to enter from openings in the case. Doing so may cause fire or electric shock. 

6. Turn OFF the Controller power supply before mounting or removing an Antenna or Amplifier. 

7. If an error is detected in any Product, immediately stop operation and turn OFF the power supply. Consult with an 

OMRON representative. 

8. Dispose of the Products as industrial waste. 

9. Observe all warnings and precautions given in the body of this manual. 

10.Do not touch the product immediately after usage at high temperatures. Doing so may occasionally result in burning. 

 

Содержание V680-D1KP66T-SP

Страница 1: ...RFID SYSTEM V680 Series User s Manual FL Remote ID V680 HAM42 FRT Antenna V680 HS63 SP ID Tag V680 D1KP66T SP...

Страница 2: ...observe the following items when using the RFID System Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems Read and under...

Страница 3: ...RON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WA...

Страница 4: ...t the uses listed may be suitable for the products z Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this manual z Nuclear...

Страница 5: ...ish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dime...

Страница 6: ...that may cause undesired operation FCC Part15 subpart B NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules Thes...

Страница 7: ...ests for the appropriate requirements of the following relevant standards Radio EN 300 330 2V1 1 1 06 2001 EN 300 330 1V1 3 2 12 2002 EMC EN 301 489 3V1 4 1 08 2002 EN 301 489 1V1 5 1 11 2004 Safety E...

Страница 8: ...ble 5 Do not allow water or pieces of wire to enter from openings in the case Doing so may cause fire or electric shock 6 Turn OFF the Controller power supply before mounting or removing an Antenna or...

Страница 9: ...that can affect communications with the Tags If any of these devices are nearby communications with Tags may be affected or Tags may be destroyed If the product is to be used near such devices check...

Страница 10: ...where the specified ambient storage humidity range is exceeded Locations where the product would be directly subjected to vibration or shock exceeding specifications Locations subject to contact with...

Страница 11: ...nd functions 14 2 1 Part names 14 2 2 I O Specifications 19 2 2 1 Allocated I O 19 2 2 2 Signal functions 20 2 3 Memory map 21 2 4 ID tag communication functions 22 2 4 1 Operational mode 22 3 Communi...

Страница 12: ...3 1 4 Bit clear 26 3 1 5 Data fill 27 3 1 6 Noise measurement 28 3 2 Timing chart 29 4 Appendix 30 4 1 Specifications 30 4 2 Dimensions 32...

Страница 13: ...the electromagnetic induction type and is a product in accordance with International Standard ISO IEC18000 3 ISO IEC15693 of the RFID system 1 2 System Configuration PLC FL REMOTE Master unit HUB FL R...

Страница 14: ...TE PIN No Name Description 1 TX_D1 Tranceive data output 2 TX_D1 Tranceive data output 3 RX_D2 Receive data input 4 5 6 RX_D2 Receive data input 7 8 Hood FG Ethernet connector Power supply connector A...

Страница 15: ...nal 2 GND Analog ground Power supply connector connected to the 24VDC power supply Please use the bundled connector PIN No Name Description 1 V 24VDC terminal 2 GND Ground terminal 3 GR Functional ear...

Страница 16: ...ote IO Green and Red blinking Connected to network Setting error Red Duplicate node address Red blinking Not connected to network Unlit Not connected to network TR ID transmission indicator Status Mea...

Страница 17: ......

Страница 18: ...Name Description 0 Trigger mode When the trigger signal is input from the plc FL REMOTE ID begins the communication with the ID tag and outputs the communication result to the plc 1 Auto mode When th...

Страница 19: ...15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 CMD LEN CIO 0 OUTPUT TIME WR PROTECT VERIFY HISPD TRG INHIBIT 3 2 1 0 3 2 1 0 ADDR CIO 1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 OD1 OD0 CIO 2 7 6 5 4 3 2 1 0 7 6 5...

Страница 20: ...ite verification 0 With write verification 1 Without write verification WR PROTECT Write protection function disable 0 Enabled 1 Disabled OUTPUT TIME Output time setting 0 100ms 1 500ms Slave unit to...

Страница 21: ...memory area of up to 1 Kbytes Each address of the memory area specifies one byte A single byte of data can be written to one address Address Data 0000H to 0007H 1block 0008H to 0100H to 0200H to 0300...

Страница 22: ...led in work or the palette is detected in the communication area of the antenna by the sensor or the switch and the control signal trigger signal is output from the plc to FL REMOTE ID This FL REMOTE...

Страница 23: ...ion NORM 1 0 or 1 Normal completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication ID 32 Read data Example Data read of 3 bytes from 120H addresses Outp...

Страница 24: ...1 Normal completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication Example Data write of 3 bytes from 321H addresses Output bits 15 14 13 12 11 10 9 8...

Страница 25: ...ompletion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication ID 32 Data after bit set Example Bit set of 1 byte from FFH addresses Output bits 15 14 13 12 1...

Страница 26: ...l completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication ID 32 Data after bit clear Example Bit clear of 4 bytes from FH addresses Output bits 15 14...

Страница 27: ...r 1 Normal completion ERR 1 0 or 1 Abnormal completion ERR_SUB 1 0 or 1 Abnormal completion for ID tag communication Example Data fill of 16 bytes from 6H addresses Output bits 15 14 13 12 11 10 9 8 7...

Страница 28: ...Abnormal completion ID 32 Measurement result ID0 Average value 00 63H ID1 Maximum value 00 63H ID2 Minimum value 00 63H ID3 00H fixed Example Output bits 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 CIO 0 0...

Страница 29: ...E ID makes NORM 1 on Please make TRG 0 off after the NORM signal turn to 1 on BUSY and NORM when FL REMOTE ID confirms TRG is turned off When ID tag is outside the communication area F The plc makes T...

Страница 30: ...al durability 150m s2 3times each in 6 directions Degree of protection Panel mounting conforms to IP20 Material PC ABS resin Weight Approx 150g Mounting method DIN Track or M4 screws Antenna V680 HS63...

Страница 31: ...rage 40 to 110 no freezing no dew condensation Ambient humidity Operating 35 to 95 RH storage 35 to 95 RH no freezing no dew condensation Vibration resistance Mechanical durability 10 to 2 000Hz doubl...

Страница 32: ...4 2 Dimensions FL REMOTE ID V680 HAM42 FRT...

Страница 33: ...Antenna V680 HS63 SP ID tag V680 D1KP66T SP...

Отзывы: