3.1.2.
Data write
<Master unit to Slave unit>
Signal
Length
Data
Description
CMD 4 0001B
Data
write
LEN
4
1H to 4H
Data length
ADDR
16
0000H to FFFFH Start address
OD 32
-
Write
data
<Slave unit to Master unit>
Signal
Length
Data
Description
NORM
1
0 or 1
Normal completion
ERR*
1
0 or 1
Abnormal completion
ERR_SUB*
1
0 or 1
Abnormal completion for ID tag communication
<Example>
Data write of 3 bytes from 321H addresses
Output bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
CIO+0
0 0 0 * * * * * 0 0 0 1 0 0 1 1
CIO+1
0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 1
CIO+2
0 1 1 1 1 0 0 0 0 0 0 1 0 0 1 0
CIO+3
0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 1
Data write
3 bytes
Change the setting if necessary
Fixed
321H address
12H
Fixed
78H
ABH
Содержание V680-D1KP66T-SP
Страница 17: ......
Страница 32: ...4 2 Dimensions FL REMOTE ID V680 HAM42 FRT...
Страница 33: ...Antenna V680 HS63 SP ID tag V680 D1KP66T SP...