47
CIDRW System
User’s Manual
SECTION 4
Command/Response Format
SECTION 4
Reading from/Writing to ID Tags
Example 1: Getting the Communications History of Amplifier Unit
The following response is returned if there are 32,000 total communications, 30,000 successful communications, and
2,000 failed communications.
■
CLEAR COMMUNICATIONS HISTORY
This command clears the communications history.
■
NOISE MEASUREMENT
The levels of noise in the vicinity of the CIDRW Head are measured and the noise level is expressed
numerically in the range "00" to "99."
The response code (when normal: 00) and the noise level "00" to "99" are returned.
Influence of background noise on communications distance
Refer to
Command code
CR
1
6
0Dh
Response
code
Total number of com-
munications
Total number of suc-
cessful communica-
tions
Total number of failed
communications
CR
0
0
7
D
0
0
7
5
3
0
0
7
D
0
0Dh
Command code
CR
1
7
0Dh
Response
code
CR
0
0
0Dh
Command code
CR
4
0
0Dh
Response code
Noise level
CR
0
0
0Dh
Command
Response
Command
Response
Command
Response
Содержание V640 Series
Страница 22: ...20 SECTION 1 Flowchart for Getting Started CIDRW System User s Manual SECTION 1 Product Outline MEMO...
Страница 52: ...50 SECTION 4 Command Response Format CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags MEMO...
Страница 68: ...66 SECTION 5 Window Configuration CIDRW System User s Manual SECTION 5 Browser Interface MEMO...
Страница 69: ...SECTION 6 Troubleshooting 67 CIDRW System User s Manual SECTION 6 Troubleshooting Troubleshooting 68...
Страница 76: ...74 SECTION 6 Troubleshooting CIDRW System User s Manual SECTION 6 Troubleshooting MEMO...
Страница 119: ......