CIDRW System
User’s Manual
SECTION 7
Char
act
erist
ic Da
ta
Ac
cord
ing
to
Condition
s of Use
SECTION 7
Appendix
107
Communications Time
Regardless of whether SECS is used or not, take the time required for processing between the host
device and Amplifier Units into account when designing the system.
Communications time calculation formula (unit: ms)
READ: 138.7
×
(number of pages) + 10.0
WRITE, SAME WRITE: 379.8
×
(number of pages) + 145.4
BYTE WRITE: 383.0
×
(number of pages/8) + 249.0
TAT calculation formula (units: ms)
TAT = command and response transmission time + communications time
*The command and response transmission time differs depending on the network environment.
For example: Command and response transemission time is about from 10 to 40msec, when
connect between PC and the Amplifier Unit directly by the lan cable(100M).
Time
Description
Communications time
This is the time required for communications between an ID Tag and the CIDRW Head.
TAT
This is the time required for processing at the Amplifier Unit, seen from the host device.
Host
Amplifier Unit
Command
Response
Communications time
TAT
Rounding up
Содержание V640 Series
Страница 22: ...20 SECTION 1 Flowchart for Getting Started CIDRW System User s Manual SECTION 1 Product Outline MEMO...
Страница 52: ...50 SECTION 4 Command Response Format CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags MEMO...
Страница 68: ...66 SECTION 5 Window Configuration CIDRW System User s Manual SECTION 5 Browser Interface MEMO...
Страница 69: ...SECTION 6 Troubleshooting 67 CIDRW System User s Manual SECTION 6 Troubleshooting Troubleshooting 68...
Страница 76: ...74 SECTION 6 Troubleshooting CIDRW System User s Manual SECTION 6 Troubleshooting MEMO...
Страница 119: ......