40
SECTION 4
Command/Response Format
CIDRW System
User’s Manual
SECTION 4
Reading from/Writing to ID Tags
■
TEST
Performs a communications test on communications between the host device and Amplifier Unit.
When an Amplifier Unit receives a test command, it sends the response code and command test data
to the host device as the response.
* Number of data n < 136 (2-character units)
The response code (when normal: 00) and the received test data are returned.
Example: Performing a Test for the Amplifier Unit Using the Data 12345678
Command code
Test data
CR
Data 1
•••
Data n
1
0
0Dh
Parameter Description
Parameter
Description
Test data
The data to be sent in the test is specified with a hexadecimal value. (270 characters max.)
However, note that odd numbers of characters cannot be used.
Response
code
Test data
CR
Data 1
•••
Data n
0
0
0Dh
Command code
Test data
CR
Data 1
Data 2
Data 3
Data 4
1
0
1
2
3
4
5
6
7
8
0Dh
Response
code
Test data
CR
Data 1
Data 2
Data 3
Data 4
0
0
1
2
3
4
5
6
7
8
0Dh
Command
Response
Command
Response
Содержание V640 Series
Страница 22: ...20 SECTION 1 Flowchart for Getting Started CIDRW System User s Manual SECTION 1 Product Outline MEMO...
Страница 52: ...50 SECTION 4 Command Response Format CIDRW System User s Manual SECTION 4 Reading from Writing to ID Tags MEMO...
Страница 68: ...66 SECTION 5 Window Configuration CIDRW System User s Manual SECTION 5 Browser Interface MEMO...
Страница 69: ...SECTION 6 Troubleshooting 67 CIDRW System User s Manual SECTION 6 Troubleshooting Troubleshooting 68...
Страница 76: ...74 SECTION 6 Troubleshooting CIDRW System User s Manual SECTION 6 Troubleshooting MEMO...
Страница 119: ......