4
Section 1 - Introduction and Getting Started
V520-LHA7127
5.
In a Microsoft Windows 3.1 environment, set the communication parameters using the Terminal function of
Windows.
a) From Window’s
Program Manager
Main Menu, select
Terminal
.
b) From the
Terminal
menu, select Settings.
c)
From the
Settings
menu, select Terminal Emulation.
d) Set the emulation to TTY (generic).
e) From the
Settings
menu, select Terminal Preferences and select the following Terminal modes:
• Line Wrap
• Local Echo
• Sound
• CR/LF: Inbound, Outbound
• Columns: 80
f)
From the
Settings
menu, select Communications, select the COM port, and communication parameters
as shown in Step 2, including no flow control.
6.
To verify that the scanner and the PC are communicating properly, send the following command from your
PC keyboard to activate the scanner’s buzzer.
Send the command: <Escape> V5 <Carriage Return>
Note
Be sure to use capital letters, e.g. “V5”, not “v5”. The buzzer should sound,
indicating that good communications have been established.
7.
A red scanning light should be visible. If it is not visible, the scanner may be in a mode that requires a
“Trigger” Command from the PC to activate it. You can exit that mode by sending the following command
from your PC keyboard:
<Escape> S7 <Carriage Return>
8.
The “Trigger” mode will now be deactivated and the red scanner light will be continuously illuminated.
This Quick Start-Up procedure will get you started. However, to best understand the full capabilities of this
scanner, you should read the complete manual.
Содержание V520-LHA7127
Страница 1: ...MANUAL USER Cat No Q07BAZ1 V520 LHA7127 Miniature High Speed CCD Fixed Position Scanner...
Страница 2: ...V520 LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual...
Страница 3: ...iv...
Страница 9: ...x Application Precautions 3...
Страница 25: ...16 Section 4 Configuring the Scanner V520 LHA7127...
Страница 27: ...18 Section 5 Application Engineering Support V500 LPN5627 V500 LPR5627...
Страница 29: ...20 Section 6 Scanner Servicing and Maintenance V520 LHA7127...
Страница 69: ...60 Appendix B Dimensional Drawings V520 LHA7127...
Страница 71: ...62 Appendix C Optical Performance Charts V520 LHA7127...
Страница 75: ...66 Appendix D PLC Touchscreen Connection Examples V520 LHA7127...