7-23
7 Tag Data Link Functions
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
7-
2 S
e
tti
ng
T
ag
Da
ta
Li
n
ks
7
7-2
-4 Cr
eating T
a
gs an
d T
ag
S
e
ts
4
Click the
In - Consume
Tab, and then click the
New
Button. The Edit Tag Dialog Box is dis-
played.
5
Enter the variable name directly into the
Name
Box. ( Example: Var_In_a)
Additional Information
•
You can use the following characters in tag names. 0 to 9, A to Z, a to z, single-byte kana, _
(underbar), and multi-byte characters (e.g., Japanese)
•
You cannot use the following characters in tag names. ! “ # $ & ‘ ( ) * + ‚ - . / : ; < = > ? @ [ ] ^ ‘
% spaces or text strings that start with numerals (0 to 9)
•
The maximum length of a tag name is 255 bytes.
•
Specify array variables,structure variables, and union variables as shown below.
•
Specifying array elements:
array [2][3]
(or array
[2,3]
) and array
[2][3][4]
(or array
[2,3,4]
)
•
Specifying structure members:
Struct.member
(Separate the member name with a period.)
•
Specifying union members:
Union.member (Separate the member name with a period.)
Precautions for Correct Use
Precautions for Correct Use
You cannot use the following notation, which specifies an I/O memory address, in the variable
name of any variable used in a tag data link.
1) Variable names that contain only single-byte numerals (Example: 001)
2) Variable names with the following single-byte letters (uppercase or lowercase) followed by
single-byte numerals
•
H (Example: H30)
•
W (Example: w30)
•
D (Example: D100)
•
E0_ to E18_
6
Input the size of the tag in bytes in the
Size
Field. Input the tag size so that it is the same as the
data type size of the variable. Select the
Use Bit Data
Check Box and change the bit size to 1 to
use BOOL variables.
7
Click the
Regist
Button to register the tag. If an I/O memory address is specified for a tag name,
the Edit Tag Dialog Box is displayed with the next consecutive address as the tag name for the
next tag. After you have registered all of the tags, click the
Close
Button.
8
Click the
Out - Produce
Tab, and then click the
New
Button. The Edit Tag Dialog Box is dis-
played. Input the output tag in the same way. Use the Fault Action setting of the output (pro-
duce) tag to specify whether to clear the output data or continue to send it when a major fault
occurs in the Controller.
Содержание Sysmac NY512-1300
Страница 290: ...9 Socket Service 9 32 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 310: ...10 FTP Server 10 20 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 324: ...11 FTP Client 11 14 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 452: ...Appendices A 66 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 ...
Страница 453: ...Index 1 NY series Industrial Panel PC Industrial Box PC Built in EtherNet IP Port User s Manual W563 I Index ...
Страница 459: ......