No.13S062-07
25/53
STC-MBE132U3V / MCE132U3V / STC-MCE132U3V-C
Product Specifications and User’s Guide
7.2.2 Frame Start Trigger (Pulse Width Trigger)
When operating in this mode, the exposure synchronizes the trigger signal.
The exposure time can be controlled by the pulse width of Frame Start trigger.
When the polarity on the Line Inverter is positive (false), the exposure can be controlled at a period of High level
of input trigger signal.
When the polarity on the Line Inverter is negative (true), the exposure can be controlled at a period of Low level
of input trigger signal.
To operate the camera in this mode, the following settings have to be set.
・
Exposure Mode: Trigger Width
・
Trigger Selector: Frame Start
・
Trigger Mode: On
(*) On Trigger Mode except Frame Start should be set Off.
Timing
7.2.3 Trigger Software
This function can apply either external signal or a software command as the trigger.
The software trigger can be applied through the “execute Trigger Software” command when the trigger is
selected on the Trigger Selector.
トリガー入力(正極性)
露光
映像出力
I/O遅延(tIPDLH)
トリガー入力(負極性)
I/O遅延(tIPDHL)
LineDebounceTime
TriggerDelay
ExposureTime
センサー内部の露光開始遅延
Trigger Delay
Exposure
VideoOut
Trigger Input
(Positive)
Trigger Input
(Negative)
I/O Delay (tIPDLH)
I/O Delay (tIPDHL)
Exposure Start Duration inside of sensor