background image

S8FS-G

10

*

Refer to 

Ratings, Characteristics, and Functions

 on page 11.

Power rating

600 W

Item

Output voltage

12 V

15 V

24 V

48 V

Efficiency 

*

100 VAC input

84% typ.

84% typ.

85% typ.

88% typ.

200 VAC input 

88% typ.

88% typ.

89% typ.

92% typ.

230 VAC input

88% typ.

88% typ.

90% typ.

92% typ.

 Input

Voltage range 

*

Single phase, 85 to 264 VAC, 120 to 350 VDC

Frequency 

*

50 /60 Hz(47 to 63 Hz)

Current 

*

100 VAC input

7.7 A typ. 

200 VAC input

3.8 A typ. 

Power factor

0.9 min.

Leakage current 

*

100 VAC input

0.5 mA max.

200 VAC input

1 mA max.

Inrush current 

*

(for a cold start at 25°C)

100 VAC input

14 A typ. 

200 VAC input

28 A typ. 

Output

Rated Output Current

50 A

40 A

27 A

13 A

Voltage adjustment range

 

*

10% to 15% (with V.ADJ)

Ripple & Noise voltage 

*

100

 to 

240

 VAC input 

170 mVp-p max.

170 mVp-p max.

280 mVp-p max.

340 mVp-p max.

Input variation influence 

*

0.5% max.

Load variation influence 

*

1.0% max.

Temperature 
variation influence

100

 to 

240

 VAC input

0.05%/°C max.

Startup time 

*

100 VAC input

1,000 ms max.

200 VAC input

1,000 ms max.

Hold time 

*

100 VAC input

30 ms typ. 

25 ms typ. 

30 ms typ. 
40 ms typ. (Extended 
hold time type)

30 ms typ. 

200 VAC input

30 ms typ. 

25 ms typ. 

30 ms typ. 
40 ms typ. (Extended 
hold time type)

30 ms typ. 

Additional 
functions

Overload protection

Yes, automatic reset

Overvoltage protection 

*

Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) 

Overheat protection

Yes, power shut off (shut off the input voltage and turn on the input again)

Series operation

Yes (For up to two Power Supplies, external diodes are required.)

Parallel operation

Yes (up to five Power Supplies, S8FS-G60024 (models with parallel operation option) only).

Remote sensing

No

Remote control

Yes (Only Remote control)

Output indicator

Yes (LED: Green)

Insulation

Withstand voltage

3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
Only Remote control
500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA

Insulation resistance

100 M

Ω

 min. (between all output terminals and all input terminals/PE terminals) at 500 VDC

Environment

Ambient operating temperature

20 to 70°C (Derating is required according to the temperature.) (with no condensation or icing)

Storage temperature

25 to 75°C (with no condensation or icing)

Ambient operating humidity

90% max. (Storage humidity: 90% max.)

Vibration resistance

10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions

Shock resistance

150 m/s

2

, 3 times each in ±X, ±Y, ±Z directions

Reliability

MTBF

135,000 hrs min.

Life expectancy 

*

10 years min.

Construction

Dimensions (W×H×D)

Refer to

 Dimensions

 on 

page 26

.

Weight

1,050 g

Cooling fan

Yes 

Degree of protection

---

Standards

Harmonic current emissions

Conforms to EN 61000-3-2

EMI 

*

Conducted Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B

Radiated Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B

EMS

Conforms to EN 61204-3 high severity levels

Safety Standards

UL 508 (Listing, excluding models with remote control option)
UL 508 (Recognition, models with remote control option)
UL 60950-1, UL 62368-1 (Recognition, OVCII [

 3,000 m], Pol2)

CSA C22.2 No.107.1 (excluding models with remote control option)
CSA C22.2 No.60950-1, No.62368-1 (excluding models with remote control option)
EN 50178 (OVCIII [

 2,000 m], OVCII [> 2,000 m and 

 3,000 m], Pol2)

EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [

 3,000 m], Pol2)

Conforms to EN/IEC 61558-2-16
Conforms to PELV (EN/IEC 60204-1)

Marine Standards

No

SEMI

Conforms to F47-0706 (200 VAC input)

Содержание S8FS-G Series

Страница 1: ...below Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 29 Output voltage Power rating 15 W 30 W 50 W 100 W 150 W 300 W 600 W 5 V Yes Yes Yes Yes Yes 12 V Yes Yes Yes Y...

Страница 2: ...5CD 24 V 1 5 A S8FS G03024CD 50 W 5 V 8 A 1 S8FS G05005CD 12 V 4 3 A S8FS G05012CD 15 V 3 5 A S8FS G05015CD 24 V 2 2 A S8FS G05024CD 100 W 5 V 16 A 2 S8FS G10005CD 12 V 8 5 A S8FS G10012CD 15 V 7 A S8...

Страница 3: ...V 3 5 A S8FS G05015C 24 V 2 2 A S8FS G05024C 100 W 5 V 16 A 2 S8FS G10005C 12 V 8 5 A S8FS G10012C 15 V 7 A S8FS G10015C 24 V 4 5 A S8FS G10024C 150 W 5 V 21 A 3 S8FS G15005C 12 V 13 A S8FS G15012C 15...

Страница 4: ...cator Yes LED Green Insulation Withstand voltage 3 kVAC for 1 min between all input terminals and output terminals current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals cu...

Страница 5: ...s LED Green Insulation Withstand voltage 3 kVAC for 1 min between all input terminals and output terminals current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals current cu...

Страница 6: ...kVAC for 1 min between all input terminals and output terminals current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals current cutoff 20 mA 1 kVAC for 1 min between all ou...

Страница 7: ...current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals current cutoff 20 mA 1 kVAC for 1 min between all output terminals and PE terminals current cutoff 20 mA Only Remote...

Страница 8: ...tput terminals current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals current cutoff 20 mA 1 kVAC for 1 min between all output terminals and PE terminals current cutoff 20...

Страница 9: ...ator Yes LED Green Insulation Withstand voltage 3 kVAC for 1 min between all input terminals and output terminals current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals cur...

Страница 10: ...LED Green Insulation Withstand voltage 3 kVAC for 1 min between all input terminals and output terminals current cutoff 20 mA 2 kVAC for 1 min between all input terminals and PE terminals current cuto...

Страница 11: ...d output current are satisfied Leakage current The values are determined according to the Act on Power Supply Safety of Electrical Appliances and Materials Inrush current for a cold start at 25 C For...

Страница 12: ...breakers so that external fuses will not burn out or breakers will not operate due to inrush current Ripple Noise Voltage The specified standard for the ripple voltage noise was measured with a measu...

Страница 13: ...N Rectifier Smoothing circuit Rectifier smoothing circuit S8FS G015 15 W S8FS G030 30 W S8FS G050 50 W S8FS G100 100 W S8FS G150 150 W V V DC OUTPUT V V RC RC REMOTE CONTROL Only Remote control AC L...

Страница 14: ...rcuit Drive circuit 250 VAC 12 A HBC S8FS G300 300 W S8FS G600 600 W Voltage detection circuit Photocoupler Over voltage detection circuit Over current detection circuit Current detection circuit Over...

Страница 15: ...h terminal Connect the ground line to this terminal 2 4 V1 DC output terminals Connect the load lines to these terminals 5 V2 6 V1 7 V2 8 Output indicator DC ON green Lights while a direct current DC...

Страница 16: ...below the range of the derating curve shown above by the dashed line by multiplying with the coefficient 0 9 Note At a voltage below 100 VAC reduce the load at the rate of 1 3 V Parallel Operation Fo...

Страница 17: ...elow 100 VDC reduce the load by multiplying with the coefficient 0 9 300 W and 600 W Note At a voltage below 100 VAC reduce the load at the rate of 1 3 V 70 45 C max 50 C 60 C 70 C 0 500 1 000 1 500 2...

Страница 18: ...a DC power Supply external power supply other than this Power Supply Connectors used Applicable crimp tool YC 110R J S T Mfg Co Ltd or YRS 110 J S T Mfg Co Ltd Note 1 When the external power supply i...

Страница 19: ...88 5 0 5 40 0 5 Two M3 55 0 5 Two 3 5 dia Two M3 87 0 5 Two 3 5 dia 74 0 5 5 max 5 32 5 117 7 1 14 3 8 2 9 5 Five M3 5 36 2 1 49 5 3 5 Sliding 6 2 max S8FS G015 CD S8FS G030 CD 17 5 55 0 5 20 5 5 40 0...

Страница 20: ...Two M3 55 0 5 Two 3 5 dia 87 0 5 Two M3 74 0 5 Two 3 5 dia 8 2 9 5 5 117 7 1 14 3 37 2 1 49 5 47 5 5 5 Sliding 8 2 max 5 max Five M3 5 S8FS G050 CD 18 5 55 0 5 20 5 5 55 5 0 5 45 5 97 1 36 1 29 3 5 3...

Страница 21: ...3 5 dia Three M3 Depth 6 mm max S8FS G100 C Panel mounting holes dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Side Mounting Bottom Mounting 122 5 0...

Страница 22: ...Input L Input N 3 5 dia 3 5 dia Three M3 Depth 6 mm max Two M3 Depth 5 mm max S8FS G100 E Panel mounting holes dimensions Using the mounting holes in the Power Supply Using the screw holes in the Powe...

Страница 23: ...even M3 5 Two M3 Depth 5 mm max S8FS G150 C Panel mounting holes dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Side Mounting Bottom Mounting 152 5 0...

Страница 24: ...mm max Three M3 Depth 6 mm max 3 5 dia 3 5 dia Output Output Input L Input N S8FS G150 E Panel mounting holes dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power...

Страница 25: ...C Panel mounting holes dimensions Using the screw holes in the Power Supply Side Mounting Bottom Mounting 64 0 5 Two 4 5 dia 74 0 5 20 0 5 Four 4 5 dia 8 2 9 5 201 1 14 1 5 48 5 53 5 42 5 1 4 8 Seven...

Страница 26: ...Panel mounting holes dimensions Using the screw holes in the Power Supply Side Mounting Bottom Mounting 150 0 5 100 0 5 Four 4 5 dia 150 0 5 38 0 5 Four 4 5 dia S8FS G600 CD Four M4 8 2 9 5 20 5 10 8...

Страница 27: ...is provided with the Power Supply as a standard accessory You can purchase another one if your Cover is damaged or lost Power rating Mounting direction Model 15 W 30 W 50 W 100 W 150 W and 300 W Fron...

Страница 28: ...at the Unit will be subject to vibration or shock use a steel DIN Rail Otherwise metallic filings may result from aluminum abrasion 4 5 15 25 25 10 10 1 000 500 25 25 15 5 35 0 3 7 3 0 15 27 0 15 1 Va...

Страница 29: ...asures to ensure proper heat dissipation to increase the long term reliability of the Power Supply Be sure to allow convection in the atmosphere around devices when mounting Do not use in locations wh...

Страница 30: ...00 20 A S8FS G600 30 A Use two terminals together if the current flow is higher than the rated terminal current Terminals and Wiring Connector type Note 1 The current capacity per output terminal is 5...

Страница 31: ...If the list of models that support series connection of outputs says that an external diode is not required an external diode is also not required for positive negative outputs Use the following info...

Страница 32: ...s short circuited Checking Overvoltage or Internal Protection Turn the power supply OFF leave it OFF for at least three minutes and then turn it ON again to see if this clears the condition Checking O...