10.5 Model Specifications (Three-Phase 400 V Class)
SIEPCYEUOQ2V01A Q2V Technical Manual
297
Model
Duty Rating
4018
4023
4031
4038
4044
4060
Output
Rated Output
Capacity
(kVA)
HD
11.3
13.7
18.3
23.6
29.7
34.3
ND
13.3
17.8
23.6
29
33.5
45.7
Rated Output
Current (A)
HD
14.8
18.0
24.0
31.0
39.0
45.0
ND
17.5
23.4
31.0
38.0
44.0
60
Overload Tolerance
•
HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10
minutes.
•
ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10
minutes.
Note:
Derating may be necessary for applications that start and stop frequently.
Carrier Frequency
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Maximum Output Voltage
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output Frequency
•
V/f Control, OLVector, PM OLVector: 590 Hz
•
PM AOLVector: 270 Hz
•
EZ Vector: 120 Hz
Measures for
Harmonics
DC reactor
External options
Braking Device
Braking Transistor
Standard internal characteristics
EMC Filter
EMC Filter
IEC61800-3
Category C2 (Conducted emission)
Power Supply
Rated Voltage/Rated Frequency
Three-phase AC power supply 380 V to 480 V at 50/60 Hz
Permitted Voltage Fluctuation
-15% to +10%
Permitted Frequency Fluctuation
±5%
Input Power
(kVA)
HD
14
18
27
36
47
55
ND
18
22
35
40
55
74
*1
The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2
The rated output capacity is calculated with a rated output voltage of 440 V.
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...