Power Connector Wiring Materials
Use the power supply connector that was supplied to connect the power supply to the IPC Machine
Controller.
• Select power supply conductors with consideration to the voltage drop and heat generation for the
cable length at the installation environment.
• Always use twisted wires to minimize the occurrence of electrical disturbance.
• Recommended power supply conductor sizes are provided in the table.
Wire type
Conductor cross-section
Solid conductor
0.5 to 10 mm
2
Flexible conductor
0.5 to 6 mm
2
Flexible conductor, with ferrule and no plastic sleeve
0.5 to 6 mm
2
Flexible conductor, with ferrule and plastic sleeve
0.5 to 4 mm
2
Minimum AWG according to UL/cUL
20
Maximum AWG according to UL/cUL
8
• Power Supply Connector
DC Power Supply
The OMRON S8VK-series power supply is recommended for use with the IPC Machine Controller.
Additional Information
• Refer to
on page 3 - 26 for more information.
• Refer to
4-1-3 Power Consumption Specifications
on page 4 - 4 for power consumption de-
tails.
5 Installation
5 - 34
NY-series Industrial Panel PC Hardware User's Manual (W557)
Содержание NY532-1*00-111*13**0
Страница 42: ...Sections in this Manual 40 NY series Industrial Panel PC Hardware User s Manual W557...
Страница 86: ...3 Hardware Overview 3 28 NY series Industrial Panel PC Hardware User s Manual W557...
Страница 160: ...5 Installation 5 48 NY series Industrial Panel PC Hardware User s Manual W557...
Страница 208: ...Appendices A 16 NY series Industrial Panel PC Hardware User s Manual W557...
Страница 209: ...I Index I 1 NY series Industrial Panel PC Hardware User s Manual W557 I...
Страница 212: ......
Страница 213: ......