26

Creating Character Strings

This section explains the procedures to show texts or character strings on a 
screen. It also describes how to change the character attributes such as 
font, size and color. This way, the character string will stand out.

Example of creating a character string

In this example, the character string “Value” is outlined.

Creating a character string

1. Click the 

Character String

Button on 

the graphic bar

2. Click the position on the base screen where 

you want to input a character string.

3. Enter a character string.

4. Click the 

Character Type 

Button on the 

graphic bar.

5. The 

Character Attributes

Dialog Box will be displayed. Select the 

Outlined

Check Box. 

Click the 

OK

Button to close the setting dialog box. This completes creating a character string.

Click!!

Содержание NV3Q-MR21

Страница 1: ...the NV System Menu 7 Setting the CPIE Serial Port 8 Designing Screens Creating New Screen Data 12 Setting the NV Communications 15 Creating Switch Parts 16 Creating Lamp Parts 19 Creating Data Parts...

Страница 2: ...40 V1 NV3W MG40 V1 QVGA Models NV3Q 3 6 inch Package PLCs with Exceptional Cost CP1E Three color LED backlight of white pink and red NV3W MRxx x V1 Three color LED backlight of green orange and red NV...

Страница 3: ...ramming software for PLC Included in a package of CX One Lite Ver 4 Micro PLC Edition CX Programmer Ver 9 Included in a package of CX One Ver 4 CX Programmer Ver 9 Select from two types of software NV...

Страница 4: ...C 5 V power green Name color RD orange SD blue SG pink NV3W V1 5 VDC The NV3W V1 5 VDC type does not need a power supply unit The 5 V power is supplied from the PLC through the XW2Z 200T 4 Special Cab...

Страница 5: ...only When the CP1E uses a 24 VDC power supply Wire the 24 VDC power supply as shown below XW2Z 200T 3 2 m without 5 V Line XW2Z 500T 3 5 m without 5 V Line When the NV3W V1 24 VDC type the NV4W or the...

Страница 6: ...w Normal operation default Prohibiting moving to System Menu F ROM clear Note 1 The data saved in the F ROM includes screen data and NV configuration data Note 2 Other than the DIP switch setting you...

Страница 7: ...order Note Touch the points A B and C one at a time in order Do not press these points at the same time 2 The startup screen of the System Menu will be displayed The startup screen of the System Menu...

Страница 8: ...bit 1 Parity bit Even Communications setting for the RS 232C serial port built in the CP1E Use the PLC programming tool CX Programmer Follow the steps below to set the RS 232C serial port built in the...

Страница 9: ...m the Windows Start Menu to start the CX Programmer 2 Select PLC Auto Online Direct Online from the menu bar 3 In the Direct Online Dialog Box select USB connection for the PC PLC CP1E connection type...

Страница 10: ...ar 1 Confirm that stopping the ladder program do not cause any problem Click the Yes Button 2 The CP1E operation mode changes to the Program Mode Stopped is displayed Program Mode is displayed Transfe...

Страница 11: ...appears Select Options Transfer from PLC from the menu bar The second value from the left of Format is the stop bit Be sure to set it to 1 when the PLC is connected to an NV Click Click 3 The PLC sett...

Страница 12: ...signer from the Windows Start Menu 3 On the Select Model Dialog Box select the NV model and the NV type and enter the project name Click the Next Button NV Model Select the PT model 2 When the NV Desi...

Страница 13: ...and write data in bit units such as Backlight Light Blink In total six words are allocated The system memory is used for the PLC to control the basic operations such as switching screens The specifie...

Страница 14: ...Base Screen Parts Library A parts library contains parts such as switches lamps data displays and keyboards Your own parts library can be created by registering customized parts to reuse them Screen...

Страница 15: ...E communications was set as follows Set the same for the NV communications Mode Host Link Baud rate 115 200 bps Data length 7 Stop bit 1 Parity bit Even The stop bit for the NV serial communications i...

Страница 16: ...creating a switch part CIO 10 00 in the PLC is turned ON when the switch is pressed and turned OFF when it is released Momentary operation Normally the OFF label is displayed While the switch is press...

Страница 17: ...the bit address in the PLC ON OFF Indication Select either On to switch the ON OFF indication or Off not to switch it When you select On set also the switch timing Creating the switch labels 1 Select...

Страница 18: ...After setting click the OK Button to close the setting dialog box This completes creating a switch part 1 Change the character color to white Confirming the part ON OFF state by preview Select the par...

Страница 19: ...LC turns ON and OFF Example of creating a lamp part The lamp changes color depending on the ON OFF state of CIO 10 00 in the PLC The lamp is white when CIO10 00 is OFF It turns black when CIO10 00 is...

Страница 20: ...for the lamp part Double click the lamp part Select the Basic Setup Tab Set the ON OFF Bit Field Click the OK Button to close the dialog box This completes creation of the lamp part ON OFF Bit Set the...

Страница 21: ...s from the keyboard screen as well Example of creating a data part This data part indicates the value of D100 in the PLC in a decimal number The keyboard screen appears by touching the part Enter a va...

Страница 22: ...ck the Input Tab Select On Make the input settings Click the OK Button to lose the setting dialog box This completes the data part setting Supported Keyboard Specify the keyboard input method Keyboard...

Страница 23: ...art Creating a keyboard screen 1 Select File Keyboard Screen from the menu bar Click 2 The Edit Keyboard Screen Dialog Box will be displayed Click 0 and then click the Draw Button to open the keyboard...

Страница 24: ...ct the Basic Setup Tab Make a necessary setting as shown below Note This example uses the default setting Click the OK Button to close the dialog box Image The setting can be checked here Clicking a k...

Страница 25: ...drop it at any desired space on the keyboard screen 1 Use the Parts Library Standard NV3W V1 3 Use the part Data Drag and drop 2 Click the Parts Group Selection Button and then select Data Setting the...

Страница 26: ...this example the character string Value is outlined Creating a character string 1 Click the Character String Button on the graphic bar 2 Click the position on the base screen where you want to input...

Страница 27: ...image to show on the NV and copy it 3 On the NV Designer open the screen to paste the image Right click on the screen and select Paste from the context menu Alternatively press Ctrl V to paste the im...

Страница 28: ...the transfer method 1 Select PT Transfer Transfer from the menu bar Click 2 Select USB in the Communication Method Field Click the OK Button to close the Transfer Data Dialog Box 1 Communication Metho...

Страница 29: ...ferring The Transfer Data Dialog Box closes Click Use the shortcut Ctrl T Transfer is a frequently used operation Use the shortcut for your convenience Transfer Data After Clear NV Screen When this ch...

Страница 30: ...s the Watch Window to monitor and change the contents of PLC addresses from the CX Programmer Opening the Watch Window Select View Window Watch from the menu bar Double click Enter an address Enter a...

Страница 31: ...oes off Checking operation of the data part and keyboard When you touch the data part the keyboard screen appears You can enter a value The screen changes to the keyboard screen Enter a numerical valu...

Страница 32: ...base screen to an existing project The screen is used to confirm the screen switching operation 1 Start the NV Designer and open a project Double click 1 in the Screen Manager Base screen 1 will open...

Страница 33: ...e N 2 Current screen number NV PLC Word Area Screen number from PLC This word contains the number in binary of the screen specified by the PLC for the NV to display Current screen number This word con...

Страница 34: ...0 13 on the CX Programmer to change the backlight status Set the bits for the backlight color and backlight light blink and then turn ON the Backlight Control Enable Bit This is the example of NV3W MG...

Страница 35: ...NV PC NV3W V1 NV4W NV3Q Host Link SYSMAC CS CJ CP Series PC connection cable Setting 1 On the CX Programmer open a project of a CS CJ or CP series PLC Double click the PLC in the project tree The Cha...

Страница 36: ...2015 0715 0110 V411 E1 02...

Отзывы: