204
NT20 Status Control
Section 5-4
Note that if the screen is OFF by the backlight OFF or EL screen OFF func-
tion with Bit 15 ON (1), turn Bit 15 OFF (0) once and then turn it back ON
(1) to redisplay the screen.
Note
Instead of turning Bit 15 ON, a screen can be displayed by specifying its
screen number. For details on screen switching, refer to
5-1-4 Switching the
Screen Display
on page 172.
• Priority Registration for Processing (1:N NT Link Only) (Bit 14)
It is possible to register one of the multiple PTs connected by the 1:N NT
link method to have processing priority. The PT for which bit 14 is set ON
(1) is given priority over the other PTs and has a higher response speed
for display, touch switches, etc.
When bit 14 is turned OFF (0), this registration is canceled and the normal
response speed is reinstated. If priority registration is set for more than one
PT, the one for which the registration was made last will have priority.
By monitoring C200HX/HG/HE words, the unit number of the PT for which
priority registration has been set can be confirmed. For details on the mon-
itoring operation at the PLC, refer to the manual for the PLC used.
Connection to RS-232C Port of C200HX/HG/HE
Note
This is the port of the communications port.
Word
Bit
Function
CI0 265
(standard
port)
CI0 284
(port A)
(See note.)
CI0 285
(port B)
(See note.)
0
Unit No.0 Communications in progress flag, ON when connected
1
Unit No.1 Communications in progress flag, ON when connected
2
Unit No.2 Communications in progress flag, ON when connected
3
Unit No.3 Communications in progress flag, ON when connected
4
Unit No.4 Communications in progress flag, ON when connected
5
Unit No.5 Communications in progress flag, ON when connected
6
Unit No.6 Communications in progress flag, ON when connected
7
Unit No.7 Communications in progress flag, ON when connected
8
Unit No.0 Priority registration lamp, ON when registered
9
Unit No.1 Priority registration lamp, ON when registered
10
Unit No.2 Priority registration lamp, ON when registered
11
Unit No.3 Priority registration lamp, ON when registered
12
Unit No.4 Priority registration lamp, ON when registered
13
Unit No.5 Priority registration lamp, ON when registered
14
Unit No.6 Priority registration lamp, ON when registered
15
Unit No.7 Priority registration lamp, ON when registered
Содержание NT20
Страница 1: ...Programmable Terminal Cat No V091 E1 01 NT20 USER S MANUAL ...
Страница 2: ...NT series Programmable Terminal User s Manual Produced March 2007 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 9: ...x TABLE OF CONTENTS ...
Страница 15: ...xvi ...
Страница 21: ...xxii EC Directives 6 ...
Страница 37: ...16 Before Operating Section 1 6 ...
Страница 153: ...132 Transferring the Resource Data Section 3 11 ...
Страница 185: ...164 Numeral Setting Section 4 8 ...
Страница 267: ...246 Key to Programs Section 6 8 ...
Страница 281: ...260 Specifications Appendix A ...
Страница 285: ...264 Transporting and Storing PTs Appendix C ...
Страница 303: ...282 Function Restrictions Depending on the Support Tool Appendix I ...
Страница 307: ...286 Index ...
Страница 309: ...288 Revision History ...