2-2 Example System
2
2
D
e
s
ig
ni
n
g S
y
st
em
s
22
NP Introduction Manual
■
System Components
The following components are used for the shutter control system:
Display Device
• NP3-MQ000 (3-inch, 3-switch type)
• XW2Z-200T (PT-PLC connection cable)
PLC
• CP1L-L14D
-
(14-point I/O type)
• CP1W-CIF01 (RS-232C option board)
Equipment and Software for Programming
• PC
• USB cable (type A connector (male) - type B connector (female))
• NP-Designer (NP screen programming tool)
• CX-Programmer (PLC programming tool)
Inputs
• OPEN switch
: SW1 (allocated on the NP Function Switch)
• STOP switch
: SW2 (allocated on the NP Function Switch)
• CLOSE switch
: SW3 (allocated on the NP Function Switch)
• Vehicle sensor
: SEN1
• Light sensor
: SEN2
• Limit switch, turned ON when shutter is fully open
: LS1
• Limit switch, turned ON when shutter is fully closed : LS2
Outputs
• Contact for activating shutter escalation motor
: MO1
• Contact for activating shutter de-escalation motor : MO2
LS1
MO1
SEN2
SW1
SW2
SW3
SEN1
LS2
MO2