background image

CSM_NL_DS_E_2_1

1

Limit Touch Switch

NL

Application Examples

Press

Workpiece

NL

NL

NL

Paper (cloth)

NL

NL

Grounding
rod

Grounding
rod

(Ground)

NL

Bellows

Controller
Unit

Pressure

NL

Roller

Motor

NL

Controller
Unit

Ground side

Paper (cloth)

NL

Paper (cloth)

NL

Grounding rod

· Detection of paper or cloth seam
  (using indirect grounding).

· Detection of paper or cloth edge 
  (using indirect grounding).

· Thickness control of rolling plates.

· Displacement detection and control.

· Drill positioning. 
· Material positioning.

· Detection of workpiece edges.

· Detection of press completion position. 
· Detection of mistakes in workpiece
  setting or removal. 
· Detection of minute workpieces.

Object Actuates Switch and Turns 
Built-in Monitor Indicator ON

Instantaneous operation upon contact with extremely 

limited hysteresis for high-precision position detection.

Detects minute displacement or lightweight objects with 

minimal operating force.

Built-in LED indicator ensures easy operation monitoring.

DC models provide versatile functions in combination 

with the S3D2 Sensor Controller.

Be sure to read 

Safety Precautions

 on page 6 to 7 and 

Safety Precautions for All Limit Switches

.

Содержание NL1-C

Страница 1: ...ning Material positioning Detection of workpiece edges Detection of press completion position Detection of mistakes in workpiece setting or removal Detection of minute workpieces Object Actuates Switch and Turns Built in Monitor Indicator ON Instantaneous operation upon contact with extremely limited hysteresis for high precision position detection Detects minute displacement or lightweight object...

Страница 2: ...upply voltage Model Model Model NL1 12 VDC NL1 S NL1 SP NL1 SC NL2 24 VDC NL2 S NL2 SP NL2 SC Antenna only NL1 SC ANTENNA Same for NL1 and NL2 Item Model NL1 NL2 NL3 Degree of protection IP60 Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC Rated frequency 50 60 Hz Sensitivity Grounded object Contact resistance of 3 kΩ max Non grounded object Antenna to ground capacitance of 100 pF min Current cons...

Страница 3: ...Switch constantly emits a high frequency If an object comes in touch with the touch antenna Switching circuit will operate and send out output signals Constants of the oscillation circuit will change and oscillation will stop Applicable to a variety of purposes in combination with a dedicated sensor power supply Feedback circuit Oscillation circuit NOT circuit S3D Sensor Power Supply 100 VAC 200 V...

Страница 4: ...to connect the NL and the Sensor Power Supply or other devices with no built in contacts The cable can be extended up to 100 m on condition that the cable is wired in an independent conduit 0 V Output 12 VDC Brown Red Black White Blue Black 4 7 kΩ Switch main circuit 24 VDC 0 V Output Brown Red Black White Blue Black 2 2 Ω Switch main circuit Load Output 100 VAC 200 VAC Brown Red Black White Blue ...

Страница 5: ... representative for details Note Do not apply a force greater than 9 8 N to the plunger 40 5 2 1 2 dia 1 2 90 5 2 10 5 31 22 5 8 6 3 5 1 The coil spring antenna is movable in any direction Make sure that the angle of the antenna is within 30 to the FP free position after the antenna comes into contact with the object 2 A standard 3 m high frequency coaxial cable is provided 1 6 dia Two M22 x 1 mou...

Страница 6: ... there is no electrical continuity between the antenna and the conductor Non conductive objects e g plastic ceramic glass and cloth objects can be detected by grounding them indirectly Antenna Shape and Extension If a metal plate is used as an antenna by connecting it to the built in or separated antenna of the NL the surface area of the metal plate must be 200 cm2 maximum The antenna can be exten...

Страница 7: ... the NL will fail to operate Make sure that the conduit opening is free of foreign materials or cuttings The sealing of the NL uses nitrile butadiene rubber NBR which is highly oil resistive If exposed to some types of oil or chemical indoors or outdoors however the NBR may deteriorate Contact your OMRON representative for details Make sure that the load is connected according to the connection di...