<Antenna in Parallel>

If more than one NL is used in parallel or side-by-side, make sure that 
the distance between the antennas is at least 4 cm.

<Maintenance>

Make sure that the antenna is free of oil, dust, or rust, otherwise 
the antenna may not operate.

Application in Locations Subject to Water or Oil.
Do not use the NL in places where water or oil (especially water-
soluble oil) is frequently sprayed to the NL or antenna, otherwise the 
NL may malfunction.

Grounding

In order to maintain the operational reliability of the NL, be sure to 
ground the blue (black) wire of the power cable.

The blue (black) lead wire of the connection cable will be connected 
to the casing internally if the model is the NL1 or NL2. The NL1 or 
NL2 does not operate with the service power supply of the PC 
(Programmable Controller) because the negative end of the service 
power supply is not grounded. The noise immunity performance of 
the PC will be degraded if the negative end of the service power 
supply is grounded.

Provided that single-phase 200 V is supplied to the NL3, if one 
phase is grounded, the power supply will be short-circuited and a 
machinery breakdown will result. Use an isolating transformer and 
ground the secondary side of the transformer instead.

To maintain operating reliability and durability, connect the blue 
(black) line in the connecting cable to ground.

In the above case, be sure to ground the secondary side, otherwise 
the NL may not operate.

Note: The lead wire colors of the NL have been changed in compliance with the 

latest applicable JIS standards. Colors in parentheses are previous ones.

Others

Do not disassemble the NL, otherwise the internal wiring will be 
damaged and the NL will fail to operate.

Make sure that the conduit opening is free of foreign materials or 
cuttings.

The sealing of the NL uses nitrile butadiene rubber (NBR), which is 
highly oil resistive. If exposed to some types of oil or chemical 
indoors or outdoors, however, the NBR may deteriorate. Contact 
your OMRON representative for details.

Make sure that the load is connected according to the connection 
diagram. The internal circuit of the NL will break due to mistakes in 
wiring or load short-circuiting.

Note: The lead wire colors of the NL have been changed in compliance with the 

latest applicable JIS standards. Colors in parentheses are previous ones.

Remove the warning label on the end of the connection cable 
before wiring.

Load Switching

The NL3 switches AC loads. The maximum switching load varies 
with the ambient temperature as shown in the following graph of 
load characteristic curves.

Note: 1. Load (1) is an inductive load with a maximum repetitive operation rate 

of once per 5-minute period or resistive load.

2. Load (2) is an inductive load with a maximum repetitive operation rate 

of 3 times per minute.

3. Load (3) is an inductive load with a maximum repetitive operation rate 

of 30 times per minute.

4. Load (4) is an inductive load with a maximum repetitive operation rate 

of 300 times per minute.

5. Except for the resistive load, the characteristic curves cover repetitive 

operations in an ON-to-OFF ratio of 1:1. If the OFF period is extremely 
short in actual application, use 80% of the above values.

NL

NL

4 cm min.

NL

NL

4 cm min.

NL3

AC

Brown 
(Red)
Black
(White)
Blue
(Black)

Load

Brown (Red)

Incorrect

Black (White)(Output)

Blue (Black)

Power
supply

Load

Brown (Red)

Incorrect

Black (White)(Output)

Blue (Black)

Power
supply

Brown (Red)

Correct

Blue (Black)

Power
supply

Load

Black (White)
(Output)

(3)

(4)

0

(1)

NL3    Load Characteristic Curves

(2)

0.3

0.2

0.1

15

20

40

Temperature (

°

C)

Switching current (A)

60

Содержание NL1-C

Страница 1: ...ning Material positioning Detection of workpiece edges Detection of press completion position Detection of mistakes in workpiece setting or removal Detection of minute workpieces Object Actuates Switch and Turns Built in Monitor Indicator ON Instantaneous operation upon contact with extremely limited hysteresis for high precision position detection Detects minute displacement or lightweight object...

Страница 2: ...upply voltage Model Model Model NL1 12 VDC NL1 S NL1 SP NL1 SC NL2 24 VDC NL2 S NL2 SP NL2 SC Antenna only NL1 SC ANTENNA Same for NL1 and NL2 Item Model NL1 NL2 NL3 Degree of protection IP60 Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC Rated frequency 50 60 Hz Sensitivity Grounded object Contact resistance of 3 kΩ max Non grounded object Antenna to ground capacitance of 100 pF min Current cons...

Страница 3: ...Switch constantly emits a high frequency If an object comes in touch with the touch antenna Switching circuit will operate and send out output signals Constants of the oscillation circuit will change and oscillation will stop Applicable to a variety of purposes in combination with a dedicated sensor power supply Feedback circuit Oscillation circuit NOT circuit S3D Sensor Power Supply 100 VAC 200 V...

Страница 4: ...to connect the NL and the Sensor Power Supply or other devices with no built in contacts The cable can be extended up to 100 m on condition that the cable is wired in an independent conduit 0 V Output 12 VDC Brown Red Black White Blue Black 4 7 kΩ Switch main circuit 24 VDC 0 V Output Brown Red Black White Blue Black 2 2 Ω Switch main circuit Load Output 100 VAC 200 VAC Brown Red Black White Blue ...

Страница 5: ... representative for details Note Do not apply a force greater than 9 8 N to the plunger 40 5 2 1 2 dia 1 2 90 5 2 10 5 31 22 5 8 6 3 5 1 The coil spring antenna is movable in any direction Make sure that the angle of the antenna is within 30 to the FP free position after the antenna comes into contact with the object 2 A standard 3 m high frequency coaxial cable is provided 1 6 dia Two M22 x 1 mou...

Страница 6: ... there is no electrical continuity between the antenna and the conductor Non conductive objects e g plastic ceramic glass and cloth objects can be detected by grounding them indirectly Antenna Shape and Extension If a metal plate is used as an antenna by connecting it to the built in or separated antenna of the NL the surface area of the metal plate must be 200 cm2 maximum The antenna can be exten...

Страница 7: ... the NL will fail to operate Make sure that the conduit opening is free of foreign materials or cuttings The sealing of the NL uses nitrile butadiene rubber NBR which is highly oil resistive If exposed to some types of oil or chemical indoors or outdoors however the NBR may deteriorate Contact your OMRON representative for details Make sure that the load is connected according to the connection di...

Отзывы: