Safety Precautions

Refer to 

Safety Precautions for All Limit Switches

.

Make sure that the antenna does not come into contact 
with the human body, otherwise an electric shock may 
be received.

Antenna Grounded through Sensing Object

<Size of Sensing Object>

Grounded Object

If the sensing object is the following grounded conductor, its size 
will not affect the operation of the NL. Check for the presence of 
insulators sticking to the sensing object or the corrosion of the 
sensing object, however, so that the ground resistance will not 
exceed 3 k

.

Contact with Grounded Conductor
The sensing object is equivalently grounded through ground resistor R.

R: 3 k

 max.

The sensing object must not come into contact with the human body.

Non-grounded Object

If the sensing object is the following non-grounded conductor, the 
NL will operate if the capacitance between the sensing object and 
the ground is 100 pF or more. The larger the surface area of the 
sensing object is, the higher its capacitance will be. The shorter the 
distance between the sensing object and the ground is, the higher 
the capacitance will be. Furthermore, the capacitance greatly 
varies with the ground condition (e.g., dry sand, concrete, or wet 
soil).

Contact with Non-grounded Conductor
The sensing object is equivalently grounded through capacitor C.

C: 100 pF min.

<Conditions of Sensing Object>

The detection of conductors (e.g., iron, stainless steel, aluminum, 
and brass objects) poses no particular problem. A conductor 
coated with paint cannot be detected, however, because there is no 
electrical continuity between the antenna and the conductor.

Non-conductive objects (e.g., plastic, ceramic, glass, and cloth 
objects) can be detected by grounding them indirectly.

Antenna

<Shape and Extension>

If a metal plate is used as an antenna by connecting it to the built-in 
or separated antenna of the NL, the surface area of the metal plate 
must be 200 cm

2

 maximum. The antenna can be extended, provided 

that the total length of the antenna is 1 m maximum and that the 
bottom of the antenna is at least 10 cm away from the ground. Refer 
to the illustrations below.

Antenna Connection

To connect a suitable antenna to the high-frequency coaxial cable of 
the NL

@

-S, perform the following steps.

Braided Shield

The shield is connected to the casing of the NL. Pay the utmost 
attention so that the conductor connected to the antenna will not 
come into contact with the shield. Secure the shield with insulation 
tape.

If the antenna cable needs to be extended, use the separated 
antenna model. Do not use a standard cable in place of the high-
frequency coaxial cable.

 CAUTION

Precautions for Correct Use

3 k

 max.

R

Grounded

   conductor

100 pF min.

Generally, the conductor will
be detectable if the ambient
humidity is 60% to 70%RH and
the surface area of the conductor
is approximately 300 

×

 500 mm.

C

Non-grounded

conductor

NL

Fig. 1

Metal plate

200cm

2

max.

NL

NL

10 cm min.

1 m max.

Ground

Fig. 2

Fig. 3

 + ---

1 m

5

6

6

4

3

2

1

1

Antenna

High-frequency
coaxial cable

Screwing (I)

Screwing (II)

Antenna

High-frequency
coaxial cable

High-frequency
coaxial cable

Soldering

Antenna

Insulation tape

Braided shield

Conductor

Incorrect

Correct

NL

Standard cable

High-frequency coaxial cable

NL (separated
antenna model)

Antenna

Installation

Installation

Содержание NL1-C

Страница 1: ...ning Material positioning Detection of workpiece edges Detection of press completion position Detection of mistakes in workpiece setting or removal Detection of minute workpieces Object Actuates Switch and Turns Built in Monitor Indicator ON Instantaneous operation upon contact with extremely limited hysteresis for high precision position detection Detects minute displacement or lightweight object...

Страница 2: ...upply voltage Model Model Model NL1 12 VDC NL1 S NL1 SP NL1 SC NL2 24 VDC NL2 S NL2 SP NL2 SC Antenna only NL1 SC ANTENNA Same for NL1 and NL2 Item Model NL1 NL2 NL3 Degree of protection IP60 Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC Rated frequency 50 60 Hz Sensitivity Grounded object Contact resistance of 3 kΩ max Non grounded object Antenna to ground capacitance of 100 pF min Current cons...

Страница 3: ...Switch constantly emits a high frequency If an object comes in touch with the touch antenna Switching circuit will operate and send out output signals Constants of the oscillation circuit will change and oscillation will stop Applicable to a variety of purposes in combination with a dedicated sensor power supply Feedback circuit Oscillation circuit NOT circuit S3D Sensor Power Supply 100 VAC 200 V...

Страница 4: ...to connect the NL and the Sensor Power Supply or other devices with no built in contacts The cable can be extended up to 100 m on condition that the cable is wired in an independent conduit 0 V Output 12 VDC Brown Red Black White Blue Black 4 7 kΩ Switch main circuit 24 VDC 0 V Output Brown Red Black White Blue Black 2 2 Ω Switch main circuit Load Output 100 VAC 200 VAC Brown Red Black White Blue ...

Страница 5: ... representative for details Note Do not apply a force greater than 9 8 N to the plunger 40 5 2 1 2 dia 1 2 90 5 2 10 5 31 22 5 8 6 3 5 1 The coil spring antenna is movable in any direction Make sure that the angle of the antenna is within 30 to the FP free position after the antenna comes into contact with the object 2 A standard 3 m high frequency coaxial cable is provided 1 6 dia Two M22 x 1 mou...

Страница 6: ... there is no electrical continuity between the antenna and the conductor Non conductive objects e g plastic ceramic glass and cloth objects can be detected by grounding them indirectly Antenna Shape and Extension If a metal plate is used as an antenna by connecting it to the built in or separated antenna of the NL the surface area of the metal plate must be 200 cm2 maximum The antenna can be exten...

Страница 7: ... the NL will fail to operate Make sure that the conduit opening is free of foreign materials or cuttings The sealing of the NL uses nitrile butadiene rubber NBR which is highly oil resistive If exposed to some types of oil or chemical indoors or outdoors however the NBR may deteriorate Contact your OMRON representative for details Make sure that the load is connected according to the connection di...

Отзывы: