2
NL
Ordering Information
Built-in Antenna Model
Note: Each model is provided with a standard 1-m cable.
Separate Antenna Model
Note: Each model is provided with a standard 1-m cable.
Specifications
*1. The NL3 has a capacitor and resistor for the protection of the built-in SCR. Therefore, the NL3 has leakage current.
*2. The NL3 requires a current of 30 mA for circuit protection.
If the load current is less than 30 mA, connect the bleeder resistance R in
parallel with the load as shown below so that the total current of the load circuit will be 30 to 300 mA.
Obtain R from the following formula.
Make sure that the permissible power of the resistor is sufficient.
*3. Between current-carrying and non-current-carrying metal parts
Model
Built-in antenna model
Features
· Provides sufficient OT (overtravel).
· Antenna tip withstands bending.
· Ensures high-precision positioning control.
· OT of 5-mm max. (overtravel)
Antenna
Series
Power supply voltage
Model
Model
NL1
12 VDC
NL1-C
NL1-P
NL2
24 VDC
NL2-C
NL2-P
NL3
100 VAC
NL3-C 100V
NL3-P 100V
200 VAC
NL3-C 200V
NL3-P 200V
Antenna only
NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3)
---
Model
Separate antenna model
Features · Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used.
Antenna
Series
Power supply voltage
Model
Model
Model
NL1
12 VDC
NL1-S
NL1-SP
NL1-SC
NL2
24 VDC
NL2-S
NL2-SP
NL2-SC
Antenna only
---
---
NL1-SC ANTENNA (Same for NL1 and NL2)
Item
Model
NL1
NL2
NL3
Degree of protection
IP60
Supply voltage
12 VDC
24 VDC
100 VAC or 200 VAC
Rated frequency
---
50/60 Hz
Sensitivity
Grounded object: Contact resistance of 3 k
Ω
max.
Non-grounded object: Antenna-to-ground capacitance of 100 pF min.
Current consumption
8 mA
15 mA
---
Leakage current
---
Circuit: 2 mA; Antenna: 1 mA
*
1
Response time
5 ms max.
20 ms max.
Output signal
Voltage output model: 30 mA at
12 VDC with output
impedance of 4.7 k
Ω
Current output model:
24 VDC (directly switching
resistive load of 170 mA max.)
Thyristor output model:
100 or 200 VAC (directly switching resistive
load of 30 to 300 mA)
*
2
Insulation resistance
0 V (black lead wire) is connected to casing
100 M
Ω
min. at 500 VDC
*
3
Dielectric strength
0 V (black lead wire) is connected to casing
1,500 VAC at 50/60 Hz for 1 min
*
3
Pollution degree
(operating environment)
3 (IEC947-5-1)
Protection against
electric shock
Class II
Proof tracking index (PTI)
175
Switch category
D (IEC335)
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Approx. 200 m/s
2
min.
Ambient temperature
−
10
°
C to +60
°
C (with no icing)
Ambient humidity
35% to 95%RH
Weight
Approx. 370 g (NL
@
-C, -P) Approx. 550 g (NL
@
-S) Approx. 680 g (NL
@
-SP, -SC)
Coil spring
Plunger
No antenna
Plunger
with antenna
Coil spring with antenna
NL3
Black (Blue)
Power supply
100 VAC
(200 VAC)
White
(Black)
R
i
Red (Brown)
Load
V
30
−
i
R= (k
Ω
)