background image

2

NL

Ordering Information 

Built-in Antenna Model

Note: Each model is provided with a standard 1-m cable.

Separate Antenna Model

Note: Each model is provided with a standard 1-m cable.

Specifications

*1. The NL3 has a capacitor and resistor for the protection of the built-in SCR. Therefore, the NL3 has leakage current.
*2. The NL3 requires a current of 30 mA for circuit protection.

If the load current is less than 30 mA, connect the bleeder resistance R in
parallel with the load as shown below so that the total current of the load circuit will be 30 to 300 mA.
Obtain R from the following formula.

Make sure that the permissible power of the resistor is sufficient.

*3. Between current-carrying and non-current-carrying metal parts

Model

Built-in antenna model

Features

· Provides sufficient OT (overtravel).
· Antenna tip withstands bending.

· Ensures high-precision positioning control.
· OT of 5-mm max. (overtravel)

Antenna

Series

Power supply voltage

Model

Model

NL1

12 VDC

NL1-C

NL1-P

NL2

24 VDC

NL2-C

NL2-P

NL3

100 VAC

NL3-C  100V

NL3-P  100V

200 VAC

NL3-C  200V

NL3-P  200V

Antenna only

NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3)

---

Model

Separate antenna model

Features · Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used.

Antenna

Series

Power supply voltage

Model

Model

Model

NL1

12 VDC

NL1-S

NL1-SP

NL1-SC

NL2

24 VDC

NL2-S

NL2-SP

NL2-SC

Antenna only

---

---

NL1-SC ANTENNA (Same for NL1 and NL2)

Item

Model

NL1

NL2

NL3

Degree of protection

IP60

Supply voltage 

12 VDC

24 VDC

100 VAC or 200 VAC

Rated frequency

---

50/60 Hz

Sensitivity

Grounded object: Contact resistance of 3 k

 max.

Non-grounded object: Antenna-to-ground capacitance of 100 pF min.

Current consumption

8 mA

15 mA

---

Leakage current

---

Circuit: 2 mA; Antenna: 1 mA  

*

1

Response time

5 ms max.

20 ms max.

Output signal

Voltage output model: 30 mA at
12 VDC with output
impedance of 4.7 k

Current output model:
24 VDC (directly switching
resistive load of 170 mA max.)

Thyristor output model:
100 or 200 VAC (directly switching resistive 
load of 30 to 300 mA)  

*

2

Insulation resistance

0 V (black lead wire) is connected to casing

100 M

 min. at 500 VDC  

*

3

Dielectric strength

0 V (black lead wire) is connected to casing

1,500 VAC at 50/60 Hz for 1 min  

*

3

Pollution degree
(operating environment)

3 (IEC947-5-1)

Protection against 
electric shock

Class II

Proof tracking index (PTI)

175

Switch category

D (IEC335)

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

Approx. 200 m/s

2

 min.

Ambient temperature

10

°

C to +60

°

C (with no icing)

Ambient humidity

35% to 95%RH

Weight

Approx. 370 g (NL

@

-C, -P) Approx. 550 g (NL

@

-S) Approx. 680 g (NL

@

-SP, -SC)

Coil spring

Plunger

No antenna

Plunger
with antenna

Coil spring with antenna

NL3

Black (Blue)

Power supply
100 VAC
(200 VAC)

White
(Black)

R

i

Red (Brown)

Load

V

30

i

R=           (k

)

Содержание NL1-C

Страница 1: ...ning Material positioning Detection of workpiece edges Detection of press completion position Detection of mistakes in workpiece setting or removal Detection of minute workpieces Object Actuates Switch and Turns Built in Monitor Indicator ON Instantaneous operation upon contact with extremely limited hysteresis for high precision position detection Detects minute displacement or lightweight object...

Страница 2: ...upply voltage Model Model Model NL1 12 VDC NL1 S NL1 SP NL1 SC NL2 24 VDC NL2 S NL2 SP NL2 SC Antenna only NL1 SC ANTENNA Same for NL1 and NL2 Item Model NL1 NL2 NL3 Degree of protection IP60 Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC Rated frequency 50 60 Hz Sensitivity Grounded object Contact resistance of 3 kΩ max Non grounded object Antenna to ground capacitance of 100 pF min Current cons...

Страница 3: ...Switch constantly emits a high frequency If an object comes in touch with the touch antenna Switching circuit will operate and send out output signals Constants of the oscillation circuit will change and oscillation will stop Applicable to a variety of purposes in combination with a dedicated sensor power supply Feedback circuit Oscillation circuit NOT circuit S3D Sensor Power Supply 100 VAC 200 V...

Страница 4: ...to connect the NL and the Sensor Power Supply or other devices with no built in contacts The cable can be extended up to 100 m on condition that the cable is wired in an independent conduit 0 V Output 12 VDC Brown Red Black White Blue Black 4 7 kΩ Switch main circuit 24 VDC 0 V Output Brown Red Black White Blue Black 2 2 Ω Switch main circuit Load Output 100 VAC 200 VAC Brown Red Black White Blue ...

Страница 5: ... representative for details Note Do not apply a force greater than 9 8 N to the plunger 40 5 2 1 2 dia 1 2 90 5 2 10 5 31 22 5 8 6 3 5 1 The coil spring antenna is movable in any direction Make sure that the angle of the antenna is within 30 to the FP free position after the antenna comes into contact with the object 2 A standard 3 m high frequency coaxial cable is provided 1 6 dia Two M22 x 1 mou...

Страница 6: ... there is no electrical continuity between the antenna and the conductor Non conductive objects e g plastic ceramic glass and cloth objects can be detected by grounding them indirectly Antenna Shape and Extension If a metal plate is used as an antenna by connecting it to the built in or separated antenna of the NL the surface area of the metal plate must be 200 cm2 maximum The antenna can be exten...

Страница 7: ... the NL will fail to operate Make sure that the conduit opening is free of foreign materials or cuttings The sealing of the NL uses nitrile butadiene rubber NBR which is highly oil resistive If exposed to some types of oil or chemical indoors or outdoors however the NBR may deteriorate Contact your OMRON representative for details Make sure that the load is connected according to the connection di...

Отзывы: