4 Robot Instructions
4 - 36
NJ-series NJ Robotics CPU Unit User’s Manual (W539)
The setting of
TransitionParameter
(Transition Parameters) varies depending on whether
Transition-
Mode
(Transition Mode) is set to
_mcTMStartHeight
(Start height) or
_mcTMStartRemainingTime
(Start
remaining time).
_mcTMStartHeight (Start height)
Refer to
_mcTMStartHeight (Start Height)
on page 4-86 for details on
_mcTMStartHeight
(Start
height).
_mcTMStartRemainingTime (Start remaining time)
Refer to
_mcTMStartRemainingTime (Start Remaining Time)
on page 4-88 for details on
_mcTM-
StartRemainingTime
(Start remaining time).
TransitionParameter (Transition Parameters)
Name
Data
type
Valid range
Description
TransitionParameter [0]
LREAL
Positive number
or 0
Transition Start Height (The height at which the
transition is started) [mm]
TransitionParameter [1] to
[7] (Reserved)
LREAL
0
(Reserved)
Name
Data
type
Valid range
Description
TransitionParameter [0]
LREAL
Positive number
or 0
Transition Start Time (The time at which the tran-
sition is started) [ms]
TransitionParameter [1] to
[7] (Reserved)
LREAL
0
(Reserved)
Timing Charts
16#0000
Execute
Done
Busy
Active
CommandAborted
Error
ErrorID
Содержание NJ501-4300
Страница 13: ...11 CONTENTS NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 40: ...Revision History 38 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 90: ...2 Features of NJ Robotics CPU Unit 2 40 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 204: ...5 Vision Robot Integrated Simulation 5 6 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 308: ...6 Troubleshooting 6 104 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Страница 333: ...I 1 I NJ series NJ Robotics CPU Unit User s Manual W539 Index ...
Страница 335: ......