35
SECTION 11
Connection to the Machine Control Circuit
!WARNING
This product is designed for use on a 24 VDC, negative ground (protective
earth) electrical system only. Never connect the MS4800 system to a positive
ground (protective earth) system. With a positive ground (protective earth)
wiring scheme, certain simultaneous shorts of both safety outputs may not be
detected and the guarded machine may not stop, resulting in severe operator
injury.
!WARNING
Never use only a single safety output to control the machine. Should this sin-
gle output fail, the machine may not stop, resulting in severe operator injury.
The machine must be connected using both safety outputs.
The table below references Pin Numbers, Wire colors and signal names being
used with the MS4800 system.
The primary cables for the MS4800 system are industry standard non-
shielded cables with an M12 female connector. The receiver and transmitter
incorporate a 0,3 m pigtail with an M12 male connector.
We recommend to use the F39-JMR and F39-JMT cables to connect the
MS4800 system to the machine control system.
Receiver cable
Pin No. 1
Input power
Brown
+24VDC
Pin No. 2
Input power
Blue
GND
Pin No. 3
Input power
Green
Functional Earth
Pin No. 4
Output signal
White
OSSD2
Pin No. 5
Input signal
Yellow
Start
Pin No. 6
Input signal
Red
EDM
Pin No. 7
Output signal
Pink
Aux
Pin No. 8
Output signal
Black
OSSD1
Transmitter cable
Pin No. 1
Input power
Blue
GND
Pin No. 2
Input power
Brown
+24VDC
Pin No. 3
Input test
White
MTS
Pin No. 4
Input test
Black
MTS Return
Pin No. 5
Input power
Green
Functional Earth
Содержание MS4800E
Страница 2: ......
Страница 4: ...iv...
Страница 6: ...vi...
Страница 20: ...2 Section...
Страница 26: ...8 MS4800FS Cascaded Series Section 4 3...
Страница 34: ...16 Optical Synchronization Section 5 4...
Страница 40: ...22 Selecting Scan Codes Section 7 7...
Страница 42: ...24 Auxiliary Output Section 8 2...
Страница 52: ...34 General Mounting Considerations Section 10 3...
Страница 56: ...38 Connection to a safety relay unit Section 11 3...
Страница 60: ...42 Using the test object Section 13 3...
Страница 62: ...44 Section...
Страница 88: ...70 Accessories Section 15 9...
Страница 90: ...72 Section...
Страница 97: ...79 EC Declaration of Conformity Section 18 3 18 3 EC Declaration of Conformity...