40
Muting Controller RM-6
Section 12-1
The MS4800 system requires a specific sequence to activate the muting func-
tion after the RM-6 is connected to the receiver. Once the RM-6 is connected
the system will not operate until either the mute module is removed or the fol-
lowing sequence is followed:
• The MS4800 will fault "71", (mute module enable and configuration
required)
1.
Turn ON the power supply of the MS4800 system and the RM6, the start
button must be pressed for app. 3 seconds until all status LEDs of the re-
ceiver SLC are flashing shortly.
2.
Release the start button while the status LEDs are flashing
3.
The MS4800 system performs a system reboot. When this sequence is
properly completed, muting function is enabled.
The status LED of the receiver turns to green and the status LED of the RM6
lights permanently.
When this sequence is properly completed, the system will enable muting.
For further information please check the user manual of the MS4800-RM6.
Содержание MS4800E
Страница 2: ......
Страница 4: ...iv...
Страница 6: ...vi...
Страница 20: ...2 Section...
Страница 26: ...8 MS4800FS Cascaded Series Section 4 3...
Страница 34: ...16 Optical Synchronization Section 5 4...
Страница 40: ...22 Selecting Scan Codes Section 7 7...
Страница 42: ...24 Auxiliary Output Section 8 2...
Страница 52: ...34 General Mounting Considerations Section 10 3...
Страница 56: ...38 Connection to a safety relay unit Section 11 3...
Страница 60: ...42 Using the test object Section 13 3...
Страница 62: ...44 Section...
Страница 88: ...70 Accessories Section 15 9...
Страница 90: ...72 Section...
Страница 97: ...79 EC Declaration of Conformity Section 18 3 18 3 EC Declaration of Conformity...