TECHNICAL
NOTE
Quantity
Part Number
Description
Version
6
7412-2000-2005
MicroHAWK ID-40, SXGA, HD, Autofocus, WHT, HS, X
1.3.0.3009
6
97-000012-01
Power Supply, 100-240 VAC, +24 VDC, M12 12-Pin Socket
6
61-000163-03
QX Cordset, Host, Ethernet, M12 8-Pin Plug (Screw-On)-to-RJ45, 3 m
6
98-9000054-01
Kit, Mounting, APG, MicroHAWK
1
NJ301-1100
NJ301 Machine Automation Controller
1.16
1
HMC-SD291
2 GB Memory Card
1
NJ-PA3001
NJ Power Supply Unit
1
NX-ECC202
EtherCAT Coupler Unit
1.2
1
NX-ID5142-1
16-Point - DC Input Module
1.0
1
NX-OD4256
8-Point - Transistor Output, DC
1.0
1
S8VK-G12024
NA Power Supply
1
XS5W-T421-EMD-K
EtherCAT I/O Cable
1
PFP-50N
DIN Track - Length: 0.5 m; Height: 7.3 mm
1
NA5-9W001B
9” NA-HMI Panel
1
E3Z-T81
E3Z Through-Beam, Infrared, Pre-Wired
3
XS6W-6LSZH8SS200CM-Y
Cat 6A Ethernet Cable, 2M, Yellow
1
N/A
16-Port 100 Mbps Ethernet Switch
Production Rates
Software
Configuration 1 – NJ301 Controller
Technical Note: MicroHAWK ID-40 360
º
Barcode Reading Solution
•
Solution tested at 100 FPM for high-contrast barcodes.
•
Typical read rate: 1 per second.
•
SYSMAC Studio, Standard Edition, version 1.23.
•
Internet browser to connect the MicroHAWK ID-40 to WebLink.
Hardware
This solution can be implemented on NJ or NX machine controllers. Two example hardware equipment lists are
provided. Configuration 1 uses an NJ301 and Configuration 2 uses an NX1P2.