background image

How to Inhale

13

Correct Use of the Unit 

How to Inhale

1

Hold the Main Unit with
your hand and start
inhalation in relaxed
posture.

Slightly slant the Main unit (the
side of Button) towards yourself.

- If medication or slobber collects on the Mesh, the unit stops nebulization. After

removing the Mask Adapter, Inhalation Mask, or Mouthpiece, turn off the power
once and absorb the medication or slobber with new gauze. 
(If a medication has high surface activity, it may exude from Mesh holes or the
Bottle Cap, or the medication may leak from the Air Port.) 

2

When you finish inhalation, push the Button to turn
off the power.

- When the optional AC Adapter is used, unplug the power plug from

the electric outlet.  (Refer to Page 10.) 

Absorb the 
medication 
or slobber.

Immerse the Vibrator in the
medication. If the Vibrator is not
immersed such as when the Main
Unit is placed on a horizontal
surface, the unit may not nebulize.

Medication

Vibrator

Air Port

- If the medication has high surface activity or viscosity such as medication

solubilizing agent or expectorant, the nebulization rate may be reduced. 

- If you push the Button and starts the unit while the Vibrator is not immersed in

the medication, 

(1) The Battery life may be shortened or the Battery Low Indicator may turn on. 

- Slant the Main Unit and check if the Vibrator is immersed in the medication,

then push the Button and start inhalation. 

- Use the unit by immersing the Vibrator of the Inhalation Port in the medication. 

- Immediately after the medication is nebulized, turn off the power. 

(2) A metallic sound may be generated, but it is not a trouble.

Do not poke the Mesh or the Vibrator
with a cotton swab or a pin.

• The Mesh will be damaged and

cannot be used.

EN-p2-20-(NE-U22)-3  3/25/02  4:48 PM  Page 13

Содержание Micro A-I-R NE-U22

Страница 1: ...cifications Option parts 22 This unit is a medical instrument Be sure to follow the instructions of a doctor and use the unit correctly For the type dose and regimen of medication be sure to follow th...

Страница 2: ...h wet hands You may suffer electric shock or get burned Do not wash the Main Unit and AC Adapter with water or hot water Do not immerse them in water The unit may experience electricity leakage or you...

Страница 3: ...when the unit is tilted To start inhalation you must assemble the unit Please read the section on How to Assemble the Main Unit and understand the points for assembling before starting to use the uni...

Страница 4: ...ator vibrates at high frequency and pushes out medication from the pores of Mesh Electrode A contact point connecting the Main Unit and the Medication Bottle Battery Low Indicator An orange light flas...

Страница 5: ...ap Locking Lever Opens the Medication Bottle Cap Do not open Medication Bottle Cap except when washing Medication Bottle Medication Bottle Cap Medication Bottle Stores the medication Medication Bottle...

Страница 6: ...stallation is complete Installation is complete Do not open the Bottle Cap Do not insert your finger into the Nebulization Port Insert the Mesh Cap perpendicular to the Medication Bottle Align these p...

Страница 7: ...rage Bag or in a clean place How to install the Inhalation Mask S How to install the Mouthpiece Installation is complete Installation is complete Installation is complete Securely cover the Main Unit...

Страница 8: ...c outlet 2 Unlock the Main Unit by pushing in both ends of the Main Unit Locking Board of the AC Adapter Connection Stand with your fingers 2 Plug in the power plug of AC Adapter to the electric outle...

Страница 9: ...ries with new ones When the Battery Low Indicator orange turns on batteries are worn out As the unit will not nebulize immediately replace both batteries with new ones You may use manganese batteries...

Страница 10: ...Bottle is 7 ml 4 Install the Mesh Cap If the Mesh Cap is not securely closed medication may leak Medication Bottle Disengaging Button Insert the Mesh Cap perpendicular to the Medication Bottle Do not...

Страница 11: ...e off the stain 6 Install the Mask Adapter 7 Install the Inhalation Mask or the Mouthpiece Align both Electrodes with each other Keep the Electrodes clean How to install the Inhalation Mask S How to i...

Страница 12: ...eep pressing the Button approximately for 2 seconds or more the unit nebulizes in Manual Nebulization Mode The unit nebulizes only while you keep on pressing the Button and stops nebulization when you...

Страница 13: ...r in the medication If the Vibrator is not immersed such as when the Main Unit is placed on a horizontal surface the unit may not nebulize Medication Vibrator Air Port If the medication has high surfa...

Страница 14: ...ity or viscosity such as medication solubilizing agent or expectorant because the medication is often left on the Mesh Please be careful not to spray water on the Main Unit Be sure to clean and store...

Страница 15: ...n Port General advice Never try to wipe off water with tissues or cloth Dust or lint left on the Mesh may affect nebulization General advice Do not wipe the Main Unit with volatile agent such as benze...

Страница 16: ...must be done after confirming the target bacteria and the effects of disinfection method Do not disinfect the unit with the disinfection solution containing sodium hypochlorite The unit may not be abl...

Страница 17: ...chase the Mesh Cap or the broken or lost accessory contact the store where you purchased the unit or the nearest OMRON dealer Medication Bottle Disengaging Button 1 Remove the Medication Bottle from t...

Страница 18: ...torage bag to avoid the Main Unit being scratched For Optional AC adapter Bundle the power cord of AC Adapter and bind it with the AC Adapter using a Cord Band as shown in the Figure General advice Do...

Страница 19: ...utton towards yourself Refer to Page 13 Remove the medication or water Refer to Page 13 Wipe off the stain Refer to Page 15 If the unit does not nebulize normally after taking the above mentioned proc...

Страница 20: ...out 30 minutes a day with the use of alkaline batteries Operating temperature and humidity 10 to 40 C 30 to 85 RH Accessories Inhalation Mask S Inhalation Mask L Mouthpiece Mask Adapter Storage Bag In...

Отзывы: