manualshive.com logo in svg
background image

6

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

 

K8AB-PA

Cat. No. N147-E1-01

Safety Precautions

Precautions for Safe Use

Make sure to follow the instructions below to ensure safety.

1.

Do not use or keep this product in the following environments.

Outdoors, or places subject to direct sunlight or wearing 
weather.

Places where dust, iron powder, or corrosive gases (in 
particular, sulfuric or ammonia gas) exist.

Places subject to static electricity or inductive noise.

Places where water or oil come in contact with the product.

2.

Make sure to install this product in the correct direction.

3.

There is a remote risk of electric shock. Do not touch terminals 
while electricity is being supplied.

4.

Make sure to thoroughly understand all instructions in the 
Instructions Manual before handling this product.

5.

Make sure to confirm terminal makings and polarity for correct 
wiring.

6.

Tighten terminal screws firmly using the following torque.
Recommended torque: 0.54 N·m

7.

Operating ambient temperature and humidity for this product 
must be within the indicated rating when using this product.

8.

There is a remote risk of explosion. Do not use this product where 
flammable or explosive gas exists.

9.

Make sure that no weight rests on the product after installation.

10.

To enable an operator to turn off this product easily, install 
switches or circuit breakers that conform to relevant requirements 
of IEC60947-1 and IEC60947-3, and label them appropriately.

Precautions for Correct Use

For Proper Use

1.

Do not use the product in the following locations.

Places subject to radiant heat from heat generating devices.

Places subject to vibrations or physical shocks.

2.

Make sure to use setting values appropriate for the controlled 
object. Failure to do so can cause unintended operation, and may 
result in accident or corruption of the product.

3.

Do not use thinner or similar solvent for cleaning. Use commercial 
alcohol.

4.

When discarding, properly dispose of the product as industrial 
waste.

5.

Only use this product within a board whose structure allows no 
possibility for fire to escape.

About Installation

1.

When wiring, use only recommended crimp terminals.

2.

Do not block areas around the product for proper dissipation of 
heat. (If you do not secure space for heat dissipation, life cycle of 
the product will be compromised.)

3.

To avoid electrical shocks, make sure that power is not supplied to 
the product while wiring.

4.

To avoid electrical shocks, make sure that power is not supplied to 
the product when performing DIP switch settings.

Noise Countermeasures

1.

Do not install the product near devices generating strong high 
frequency waves or surges.

2.

When using a noise filter, check the voltage and current and 
install it as close to the product as possible.

3.

In order to prevent inductive noise, wire the lines connected to the 
product separately from power lines carrying high voltages or 
currents. Do not wire in parallel with or on the same cable as 
power lines. 
Other measures for reducing noise include running lines along 
separate ducts and using shield lines.

To avoid faulty operations, 
malfunctions, or failure, observe the 
following operating instructions.

1.

When turning on the power, make sure to realize rated voltage 
within 1 second from the time of first supply of electricity.

2.

Make sure to use power supply for operations, inputs, and 
transformer with the appropriate capacity and rated burden.

3.

Maintenance and handling of this product may only be performed 
by qualified personnel.

4.

Distortion ratio of input wave forms must be 30% or less. Use of 
this product with circuits that have large distortion in wave forms 
may result in unwanted operations.

5.

Using this product for thyristor controls or inverters will result in 
errors.

6.

When setting the volume, adjust the control from the minimum 
side to the maximum side.

Содержание K8AB-PA

Страница 1: ...wire power supply One SPDT output relay 6 A at 250 VAC resistive load World wide power specifications supported by one Unit switchable Relay warning status easily monitoring using LED indicator Easy w...

Страница 2: ...Operating value setting range Asymmetry rate 2 to 22 Operating value 100 operation at set value Asymmetry operating value Rated input voltage x Asymmetry set value The asymmetry operation will functio...

Страница 3: ...d exposed uncharged parts 20 M at 500 V between any charged terminals i e between input output and power supply terminals Degree of protection Terminal section IP20 Rear case IP40 Case color Munsell 5...

Страница 4: ...etry Operating Voltage Asymmetry operation condition Highest voltage Lowest voltage Asymmetry operating voltage Asymmetry operating voltage Rated input voltage V Asymmetry set value Note The rated inp...

Страница 5: ...mode OFF ON 3 phase 4 wire power monitoring mode SW3 SW4 Function Default 3 phase 3 wire mode 3 phase 4 wire mode SW3 SW4 OFF OFF Rated input voltage switch K8AB PA1 200 VAC 115 VAC OFF OFF ON OFF 22...

Страница 6: ...ruption of the product 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within...

Страница 7: ...ndividual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT TH...

Отзывы: