background image

TN

ORDERING INFORMATION

SLIM POLARIZED RELAY

TN RELAYS

RoHS Directive compatibility information
http://www.mew.co.jp/ac/e/environment/

FEATURES

1. 2 Form C Slim type

14.0(L) 

×

 9.0(W) 

×

 5.0(H) 

.551(L) 

×

 

.354(W) 

×

 .197(H)

Small header area makes higher 
density mounting possible

2. Nominal operating power: 

High sensitivity of 140mW (Single 
side stable type)

By using the highly efficient polar 
magnetic circuit “seesaw balance 
mechanism”, a nominal operating 
power of 140 mW (minimum operating 
power of 79 mW) has been achieved.

3. Surge breakdown voltage: 

1500 V FCC Part 68

4. Outstanding vibration and shock 

resistance.

Functional shock resistance: 490 m/s

2

Destructive shock resistance: 980 m/s

2

Functional vibration resistance: 
10 to 55 Hz (at double amplitude of 
3 mm 

.118 inch

)

Destructive vibration resistance: 
10 to 55 Hz (at double amplitude of 
5 mm 

.197 inch

)

5. High density mounting possible

High-efficiency magnetic circuits 
ensure low magnetic flux leakage. 
Because characteristics are little 
changed by proximity mounting, high-
density mounting is possible.

6. The use of gold-clad twin crossbar 

contacts ensures high contact 
reliability.
*We also offer a range of products 
with AgPd contacts suitable for use 
in low level load analog circuits 
(Max. 10V DC 10 mA).
*SX relays designed for low level 
loads are also available.

7. Low thermal electromotive force

As well as low power consumption of 
140 mW, use of a structure with 
separate coil and contact sections has 
reduced thermal electromotive force to 
the low level of approximately 5 

µ

V.

8. Latching types also available
9. Self-clinching terminal also 

available

10. Sealed construction allows 

automatic washing.

TYPICAL APPLICATIONS

• Communications
• Measurement equipment
• OA equipment
• Industrial machines

Coil voltage (DC)*
3, 4.5, 5, 6, 9, 12, 24, 48V

Contact arrangement
2: 2 Form C

TN

2

Terminal shape
Nil:
H:

Standard PC board terminal
Self-clinching terminal

Operating function
Nil:
L:
L2:

Single side stable
1 coil latching
2 coil latching

Notes: 1. *48 V coil type: Single side stable only

2. In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Summary of Contents for TN Relay

Page 1: ...tle changed by proximity mounting high density mounting is possible 6 The use of gold clad twin crossbar contacts ensures high contact reliability We also offer a range of products with AgPd contacts suitable for use in low level load analog circuits Max 10V DC 10 mA SX relays designed for low level loads are also available 7 Low thermal electromotive force As well as low power consumption of 140 ...

Page 2: ...C TN2 H 5V TN2 L H 5V TN2 L2 H 5V 6V DC TN2 H 6V TN2 L H 6V TN2 L2 H 6V 9V DC TN2 H 9V TN2 L H 9V TN2 L2 H 9V 12V DC TN2 H 12V TN2 L H 12V TN2 L2 H 12V 24V DC TN2 H 24V TN2 L H 24V TN2 L2 H 24V 48V DC TN2 H 48V Nominal coil voltage Pick up voltage at 20 C 68 F Drop out voltage at 20 C 68 F Nominal operating current 10 at 20 C 68 F Coil resistance 10 at 20 C 68 F Nominal operating power Max allowab...

Page 3: ...nt at same location as Initial breakdown voltage section Breakdown voltage Initial Between open contacts 750 Vrms for 1 min Detection current 10 mA Between contact and coil 1 000 Vrms for 1 min Detection current 10 mA Between contact sets 1 000 Vrms for 1 min Detection current 10 mA Surge breakdown voltage Initial Between open contacts 1 500 V 10 160µs FCC Part 68 Temperature rise at 20 C 68 F Max...

Page 4: ...et time 20 0 x x Pick up voltage 40 60 80 10 20 40 10 20 30 40 Drop out voltage Ambient temperature C 10 20 30 40 Variation ratio Y Z Z X X X X Z Z Y Y 980m s2 980m s2 980m s2 980m s2 980m s2 980m s2 Y Deenergized condition Energized condition 8 2 Malfunctional shock latching Tested sample TN2 L2 12V 6 pcs 9 1 Influence of adjacent mounting 9 2 Influence of adjacent mounting Y Z Z X X X X Z Z Y Y ...

Page 5: ... more than 10 ms to set reset the latching type relay 2 Coil connection When connecting coils refer to the wiring diagram to prevent mis operation or malfunction 3 External magnetic field Since T series relays are highly sensitive polarized relays their characteristics will be affected by a strong external magnetic field Avoid using the relay under that condition 4 Packing style The relay is packe...

Reviews: