background image

9

K3HB-C

BCD Output Cable

Note:

The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent to 17JE-23370-02 (D1) 
(manufactured by DDK)

Special Cable (for Event Inputs with 8-pin Connector)

Model

Shape

Pin arrangement

K32-BCD

Model

Appearance

Wiring

K32-DICN

Models 

w

ith Terminal Blocks 

<1> <3> 

1: 

N

/C 

3: HOLD 
5: 

COMPE

N

SATIO

N

 

7: BA

N

K4 

9: BA

N

K1 

2: S-TMR 
4: RESET 
6: COM 

8

: BA

N

K2 

10: COM 

Models 

w

ith Connectors 

<2> <4> 

10 

E3 

E2 

E1 

E6 

E5 

E4 

COM 

COM 

•  

Use terminal pin D6 as the common terminal. 

•  

Use 

N

P

N

 open collector or no-

v

oltage contacts  

for e

v

ent inp

u

t. 

    P

N

P types are also a

v

aila

b

le. 

 Up/Do

w

n Co

u

nting P

u

lse Meter: 

K3HB-C 

E3 

E2 

E1 

E6 

E5 

E4 

COM 

COM 

E  Pulse Inputs 

D6 

3.9 k

Ω 

4.7 k

Ω 

HOLD: D3 

RESET: D4 

COMPE

N

SATIO

N

: D5 

12 

V

 

COM 

N

P

N

 

P

N

Inp

u

t A 

V

oltage 

N

P

N

 

P

N

Inp

u

t B 

V

oltage 

D Event Inputs 

N

P

N

 Inp

u

t:  

K3HB-

@

N

Inp

u

t A 

Inp

u

t B 

P

N

P Inp

u

t:  

K3HB-

@

PB 

N

ote: E3 and E6, 

as 

w

ell as B6, 

are internally 
connected.  

N

ote: A 2-

w

ire DC sensor can also 

b

e connected. Check the ratings and characteristics ta

b

les, 

ho

w

e

v

er, for the connection conditions.

N

ote: The act

u

al terminal la

b

el a

bb

re

v

iates "COMPE

N

SATIO

N

" to "CMP." 

N

ote: E3 and E6, as 

w

ell as B5, 

are internally 
connected.  

COM

E3, E6

E2, E5

700 

Ω

510 

Ω

12 

V

E3, E6

E1, E4

10 k

Ω

700 

Ω

510 

Ω

12 

V

N

P

N

 Inp

u

t Model

  

N

P

N

 inp

u

t section

  

V

oltage p

u

lse inp

u

t section

 Applica

b

le Connector (Sold separately) 

   XG4M-1030 

(OMRO

N

)  

 Special Ca

b

le (Sold separately) 

   K32-DIC

N

 (OMRO

N

   (XG4M-1030 

w

ith 3-m ca

b

le) 

N/C 

COMPENSATION 

HOLD 

COM 

N/C 

RESET 

Connectable 

Sensors

ON residual voltage: 3 V

OFF leakage current:
1.5 mA max.

Connectable 

Sensors

ON voltage: 4.5 to 30 V

OFF voltage: -30 to 2 V

3

8

 mm

46.5 mm

300 mm

K3HB end

Connected de

v

ice end

(PLC, display de

v

ice, etc.)

Co

v

er:  

HDR-E50LPA5 
(man

u

fact

u

red 

b

y Honda Ts

u

shin Co., Ltd.)

Connector: HDR-E50MAG1 

(man

u

fact

u

red 

b

y Honda Ts

u

shin Co., Ltd.)

D-s

ub

 connector (37-pin female)

Co

v

er: 17JE-37H-1A 

(man

u

fact

u

red 

b

y DDK)

Connector: E

qu

i

v

alent to 17JE-13370-02 

 (man

u

fact

u

red 

b

y DDK) 

St

u

d: 17L-002A 

(man

u

fact

u

red 

b

y DDK)

1

2

3

4

5

6

7

20

21

22

23

24

25

26

27

2

8

29

30

31

32

33

34

35

36

37

10

0

10

1

10

2

10

3

10

4

10

4

O

V

ER

DATA 

V

ALID

RU

N

COMMO

N

REQUEST
MAX REQ.
MI

N

 REQ.

HOLD
RESET
POLARITY
HH
H
PASS

LL
COMMO

N

1
2

4

8

1
2

4

8

1
2

4

8

1
2

4

8

1
2

COMMO

N

4

8

7

8

9

10

11

12

13

14

15

16

17

1

8

19

3,000 mm

(3 m)

Ca

b

le marking

9

10

1

2

Pin 

N

o.

1

2

3

4

5

6

7

8

9

10

Signal name

N

/C

S-TMR

HOLD

RESET

N

/C

COM

BA

N

K4

BA

N

K2

BA

N

K1

COM

Содержание K3HB-C Series

Страница 1: ...o 240 VAC 24 VAC VDC 24 VAC VDC Optional Board Sensor Power Supply Output Boards Relay Transistor Output Boards Event Input Boards Base Units with Optional Boards 2 Sensor Power Supply Output Type Cod...

Страница 2: ...at 0 4 mA max Max applied voltage 30 VDC max OFF leakage current 0 1 mA max Reset input Bank input Output ratings depends on the model Relay output 250 VAC 30 VDC 5 A resistive load Mechanical life e...

Страница 3: ...r relay outputs 3 times each in 3 axes 6 directions Weight Approx 300 g Base Unit only Degree of protection Front panel Conforms to NEMA 4X for indoor use equivalent to IP66 Rear case IP20 Terminals I...

Страница 4: ...number of people entering an area F2 Phase dif ferential in puts This function is normally used when connected to an incremental rotary encoder The count is incremented on the falling edge of input B...

Страница 5: ...utputs 250 pulses for a 0 5 m feed the length per pulse 500 mm 0 5 m 250 2 1 The prescale value for the K3HB C is set using the mantissa X exponent Y so the prescale value 2 0000 10 X 2 000 and Y 00 2...

Страница 6: ...0 mA 0 to 5 V 1 to 5 V 0 to 10 V Allowable load impedance 500 max 5 k min Resolution Approx 10 000 Output error 0 5 FS 0 5 FS 0 15 V for 1 V or less and no output for 0 V Item Type RS 232C RS 485 Comm...

Страница 7: ...s Combination of multi drop and T branch connections for trunk and drop lines Baud rate DeviceNet 500 250 or 125 Kbps automatic follow up Communications media Special 5 wire cable 2 signal lines 2 pow...

Страница 8: ...VAC VDC A1 A2 HH H L LL PASS BCD NPN Open Collector BCD Applicable Connector Sold separately HDR E50MAG1 HONDA TSUSHIN KOGYO CO LTD Special Cable Sold separately K32 BCD OMRON HDR E50MAG1 with 0 3 m...

Страница 9: ...label abbreviates COMPENSATION to CMP Note E3 and E6 as well as B5 are internally connected COM E3 E6 E2 E5 700 510 12 V E3 E6 E1 E4 10 k 700 510 12 V NPN Input Model NPN input section Voltage pulse i...

Страница 10: ...120 100 80 60 40 20 0 20 10 0 10 20 30 40 50 60 Ambient temperature C Maximum current mA 1 Keys Micro computer Waveform shaping circuit Waveform shaping circuit Drive circuit Indications EEPROM Drive...

Страница 11: ...min between DATA VALID turning OFF and the REQUEST signal See note See note See note The K3HB BCD output model has an open collector output so wired OR connection is possible Programmable Controller C...

Страница 12: ...ameter names and error names Displays SV and monitor values Displays the position of the PV with respect to a desired scale Comparative output status indicators Level bank display Status indicators Di...

Страница 13: ...t the angles shown in the following diagram Character Size for Main Display mm Terminal M3 Terminal Cover Accessory Terminal cover included PV display SV display 14 2 4 9 3 5 7 6 96 48 1 3 12 112 100...

Страница 14: ...y protection restricts level or parameter changes using the keys to prevent unintentional key operations and malfunctions Outputs Zone and level comparative output patterns can be selected for compara...

Страница 15: ...to RUN level when there are no key operations e g max min switching bank settings using keys Other Switch between 8 comparative value banks using the keys on the front panel or external inputs A set...

Страница 16: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Страница 17: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron K3HB CNB 24VAC VDC K3HB CNB 100 240VAC...

Отзывы: