H7CR

2

Model

Economy

Standard

Reve/– Range

Number of presets

One

One

Two

One

Two

Display type

6-digit, not backlit

6-digit, backlit

4-digit, backlit

6-digit, backlit

6-digit backlit

Input type

No-voltage

Contact output

H7CR-SAL

H7CR-SBL

H7CR-SB4L

H7CR-SCL

Transistor

H7CR-SASL

H7CR-SBSL

H7CR-SBWSL

H7CR-SCSL

H7CR-SCWSL

Counter supply voltage

12 to 24 VDC

REVE/– RANGE COUNTERS

Number of presets

One

Two  (Non-independent)

Display type

6-digit LCD, backlit

6-digit LCD, backlit

Input type

No-voltage

Voltage

No-voltage

Voltage

Contact output

H7CR-C

H7CR-CV

H7CR-CW

H7CR-CWV

Transistor output

H7CR-CS

H7CR-CVS

H7CR-CWS

H7CR-CWVS

Contact output

H7CR-CG

H7CR-CVG

H7CR-CWG

H7CR-CWVG

Transistor output

H7CR-CSG

H7CR-CVSG

H7CR-CWSG

H7CR-CWVSG

Counter supply voltages

100 to  240 VAC, 50/60 Hz or 24 VAC/12 to 24 VDC

SHORT BODY COUNTERS

SOCKET-MOUNT COUNTERS

Number of presets

One

Display type

6-digit LCD, backlit

4-digit LCD, backlit

6-digit LCD, backlit

Input type

Power supply reset type

Memory backup type

Contact output

H7CR-8

H7CR-84*

H7CR-11

Transistor

H7CR-8S

H7CR-11S

Counter supply voltage

100 to 240 VAC, 50/60 Hz or 24 VAC/12 to 24 VDC

* Available with 100 to 240 VAC supply voltage only.

ACCESSORIES

12 VDC sensor
supply voltage

24 VDC sensor
supply voltage

Description

Part number

Sockets

11-pin

Bottom surface or track mounting, top screw terminals

P2CF-11

Bottom surface or track mounting, top screw terminals, finger safe terminal

P2CF-11-E

conforms to VDE0106/P100

Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3GA-11

8-pin

Bottom surface or track mounting, top screw terminals

P2CF-08

Bottom surface or track mounting, top screw terminals, finger safe terminal

P2CF-08-E

conforms to VDE0106/P100

Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-08

Terminal cover for P3G sockets, conforms to VDE0106/P100

Y92A-48G

Panel mounting adapter

Fits behind panel, ideal for side-by-side installation. Use P3G-08 sockets

Y92F-30

Protective cover

Hard plastic cover protects against dust, dirt and water; not for use with

Y92A-48B

panel covers

Soft cover with two mounting clips for front panel protection

Y92A-48F1

Shock prevention terminal cover protects wiring connections

Y92A-48T

NEMA 4 cover

Waterproof front cover

Y92A-48N

Mounting track

DIN rail, 50 cm (1.64 ft) length; 7.3 mm thick

PFP-50N

DIN rail, 1 m (3.28 ft) length; 7.3 mm thick

PFP-100N

DIN rail, 1 m (3.28 ft) length; 16 mm thick

PFP-110N2

End plate

PFP-M

Spacer

PFP-S

* Panel mounting adapter is included with H7CR-A/-B/-C digital counters.
  Order separately for use with H7CR-8/-11 counters.

Содержание H7CR-11

Страница 1: ...for positioning and production control Easy to read backlit LCD display On line change of set value 4 level key protect H7CR S short 64 mm 2 52 in body Number of presets One Display type 6 digit LCD n...

Страница 2: ...SORIES 12 VDC sensor supply voltage 24 VDC sensor supply voltage Description Part number Sockets 11 pin Bottom surface or track mounting top screw terminals P2CF 11 Bottom surface or track mounting to...

Страница 3: ...r 9 999 0 001 to 99 999 Decimal point None Rightmost 3 digits adjustments Sensor power None 12 or 24 VDC model specific supply Input signals Count reset Count reset key protect Input method No voltage...

Страница 4: ...ng to C R and Q operation operation P and Q operation resets resets resets Scaling function None 0 001 to 99 999 for 6 digit 0 001 to 9 999 for 4 digit Decimal point None Rightmost 3 digits adjustment...

Страница 5: ...ermissible ripple 20 max permissible ripple 20 max Operating voltage range 85 to 110 of rated voltage Power consumption Approx 1 7 VA at 50 Hz Approx 6 6 VA at 50 Hz 240 VAC 3 2 W at 24 VDC 240 VAC 0...

Страница 6: ...et 20 ms 1 or 20 ms 1 or 20 ms power reset 0 5 s Key protect Not applicable Response time 1 second One shot durations 10 50 100 200 10 50 100 200 and 500 ms 10 50 100 200 and 500 ms and 500 ms separat...

Страница 7: ...or phase difference inputs accepted Maximum counting speed 5 kcps Reset Present value reset to zero in Up or Up Down modes to preset with 1 stage models in Down mode and to preset 2 for 2 stage models...

Страница 8: ...e Down decrement mode Up Down A Command input mode Up Down B individual input mode H L CP2 Count H L CP1 0 1 2 3 2 1 2 3 A A H L CP2 Count H L CP1 0 1 2 3 2 1 1 2 3 2 H L H L 0 1 2 3 1 2 3 BB B B Coun...

Страница 9: ...and goes OFF after expiration of the one shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Reversible A B and C One shot output from Output 1 Sustained output...

Страница 10: ...stained output Up Down Reversible A B and C Output Mode K Present value runs continuously Output 1 latches ON at preset 1 and goes OFF after expiration of the one shot period for Output 2 One shot tim...

Страница 11: ...ed output One shot outputs can be set to 10 50 100 200 or 500 ms One shot output from Output 2 Sustained output Output Mode Q Present value runs continuously through one shot time period and returns t...

Страница 12: ...ge Output 1 goes ON for one shot whenever present value is equal to preset 1 Output 2 goes ON for one shot whenever present value is equal to preset 2 Output Mode D Present value increments and decrem...

Страница 13: ...output One shot output Sustained output level input One shot outputs can be set to 10 50 100 200 or 500 ms Notes Counting inputs are not acknowledged while the reset input is ON The compensation inpu...

Страница 14: ...ax 1 97 Eight M3 5 x 7 5 sems 3 0 12 4 5 0 18 20 3 max 0 80 Two 4 5 dia or two M4 socket mounting holes Surface Mounting Holes 4 0 16 Terminal Arrangement Internal Connections Top View 40 0 2 1 57 70...

Страница 15: ...o 4 5 dia holes 4 0 16 3 0 12 4 5 0 18 35 4 1 39 31 2 max 1 23 Two 4 5 dia or two M4 socket mounting holes Surface Mounting Holes 40 0 2 1 57 50 max 1 97 P3GA 11 Back Connecting Socket Terminal arrang...

Страница 16: ...dels 50 5 1 99 47 2 1 86 47 2 1 86 50 5 1 99 Y92A 48G Finger Safe Terminal for P3G A Conforming to VDE0106 P100 Twelve 6 4 dia holes 34 47 7 x 4 47 48 x 48 16 5 47 4 27 6 PFP 100N PFP 50N Mounting Tra...

Страница 17: ...n the two retaining screws To release the adapter lift the tab at the rear of the adapter Several counters may be mounted close together using Y92F 30 adapter as shown here When mounting two or more c...

Страница 18: ...nclude the following H7CR BW H7CR BWG H7CR B4W H7CR BWV H7CR BWVG H7CR B4WG H7CR CW H7CR CWG H7CR CWV H7CR CWVG 12 or 24 VDC sensor power supply 12 or 24 VDC sensor power supply Key protect CP1 input...

Страница 19: ...CR CVSG Applicable models include the following H7CR BWS H7CR BWSG H7CR SBWSL H7CR BWVS H7CR BWVSG H7CR SCWSL H7CR CWS H7CR CWSG H7CR CWVS H7CR CWVSG Single Preset H7CR 8 H7CR 84 H7CR 8S Single Preset...

Страница 20: ...output sensor powered by built in DC power source Counter Sensor CP1 CP2 reset etc Input use 0 V 12 or 24 VDC V 30 V max 0 V Contact Input Switch contact Counter CP1 CP2 reset etc Input use 0 V Solid...

Страница 21: ...value 8 Display key switches to the setting displays For double preset counters it switches between set values 1 and 2 9 Mode key switches from run mode to function setting mode Changes items in the f...

Страница 22: ...any settings before operating the counter Settings and display are possible with or without power supplied although power supply is required for inputs and outputs to operate Model H7CR A Economy type...

Страница 23: ...nt speed H7CR B H7CR SB inputs Used to prevent counting H7CR C H7CR SC errors caused by input interference H7CR 8 H7CR 11 Press the increment keys to set the desired speed A k on the display indicates...

Страница 24: ...re effective only after returning to the Run mode Changing the Set Value When changing the set value while the counter is operating an output will be produced if the set value ever equals the present...

Страница 25: ...RESET key or a reset input 2 Press the MODE key to scroll successively through the items that can be set Release the MODE key to select the desired item 3 Changing the counting speed or another selec...

Страница 26: ...ficient to start the counter due to the switching regulator contained in the counter s internal circuitry Connect the power supply voltage through a relay or switch in such a way that the voltage reac...

Страница 27: ...p value is on hold Mode A can be used for a start signal for sequence control equipment Mode F Go to Mode F to monitor the number of overrun objects The process value is displayed normally It is possi...

Страница 28: ...gh Ontario M1B 5V8 1 800 55 OMRON 416 286 6465 Cat No GC TMCN1 3 02 Specifications subject to change without notice Printed in the U S A OMRON ON LINE Global http www omron com USA http www omron com...

Отзывы: