28
H7CC-A
@
Counter
Note: 1.
Counting cannot be performed during reset/reset 1 input.
2.
If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
3.
If there is power interruption while output is ON, output will turn ON again when the power supply has recovered, if memory backup is
enabled.
For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered.
4.
Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
5.
The set value is from
−
99999 to 999999.
One-shot
output
Self-holding
output
Instantaneous
(equals) output
(The one-shot output time can be
set in the range 0.01 to 99.99s.)
Input mode
Operation after count
completion
UP/DOWN A, B, C
Output
mode
setting
K-2
The display continues to
increase/decrease until the
overflow or underflow value is
reached.
One-shot output only.
D
The display continues to
increase/decrease until the
overflow or underflow value is
reached.
The outputs are ON while the
count is equal.
L
The display continues to
increase/decrease until the
overflow or underflow value is
reached.
OUT1 is held while the
present value is less than or
equal to set value 1.
OUT2 is held while the
present value is greater than
or equal to set value 2.
H
The display continues to
increase/decrease until the
overflow or underflow value is
reached.
OUT1 is held while the
present value is greater than
or equal to set value 1.
OUT2 is held while the
present value is greater than
or equal to set value 2.
*
H mode is available only
when using a model as a 2-
stage counter.
0
−
99999
Reset/
reset 1
OUT1
OUT2
999999
Set value 2
Set value 1
0
−
99999
Reset/
reset 1
OUT1
OUT2
999999
Set value 2
Set value 1
0
−
99999
Reset/
reset 1
OUT1
OUT2
999999
Set value 2
Set value 1
0
−
99999
Reset/
reset 1
OUT1
OUT2
999999
Set value 2
Set value 1