background image

B-98

Solid-state timer 

H3RN

Specifications

Ratings

Note:

When using the H3RN in any place where the ambient temperature is more than 50

°

C, supply 90% to 110% of the rated voltages (12 VDC:

95% to 110% of the rated voltage).

Characteristics

Item

H3RN-1/H3RN-2

H3RN-11/H3RN-21

Time ranges

0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. 
selectable)

0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs max. 
selectable)

Rated supply voltage

24 VAC (50/60 Hz); 12, 24 VDC

Pin type

Plug-in

Operating mode

ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch

Operating voltage range

85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)
(see note)

Reset voltage

10% max. of rated supply voltage

Power consumption

24 VAC: Relay ON: approx. 0.8 VA (0.6 W) at 24 VAC, 60 Hz

Relay OFF: approx. 0.6 VA (0.4 W) at 24 VAC, 60 Hz

12 VDC: Relay ON: approx. 0.5 W at 12 VDC

Relay OFF: approx. 0.2 W at 12 VDC

24 VDC: Relay ON: approx. 0.6 W at 24 VDC

Relay OFF: approx. 0.3 W at 24 VDC

Control outputs

3 A at 250 VAC, resistive load (cos

φ

 = 1) (G6B-2

@

14P-FD-US used)

The minimum applicable load is 10 mA at 5 VDC (P reference value).

Item

H3RN-1/H3RN-2

H3RN-11/H3RN-21

Accuracy of operating time

±

1% FS max. (1 s range: 

±

1%

±

10 ms max.)

Setting error

±

15%

±

50 ms FS max.

Reset time

Min. power-opening time: 12, 24 VDC: 0.1 s max. (including halfway reset)

24 VAC:

0.5 s max. (including halfway reset)

Influence of voltage

±

2% FS max.

Influence of temperature

±

2% FS max.

Insulation resistance

100 M

 min. (at 500 VDC)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different 
poles)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance

Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions

Shock resistance

Destruction: 300 m/s

2

Malfunction: 100 m/s

2

Ambient temperature

Operating:

10

°

C to 55

°

C (with no icing)

Storage:

25

°

C to 65

°

C (with no icing)

Ambient humidity

Operating:

35% to 85%

Life expectancy

Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:

100,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)

Impulse withstand voltage

Between power terminals: 1 kV

Noise immunity

±

1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 

µ

s, 1-ns rise)

Static immunity

Destruction: 8 kV
Malfunction: 4 kV

Degree of protection

IP40 (Terminal screw sections are excluded.)

Weight

Approx. 18 g

Содержание H3RN

Страница 1: ...O 2 Time Range None Short time range 0 1 s to 10 min 1 Long time range 0 1 min to 10 hrs Ordering Information List of Models Accessories Order Separately Connecting Socket H3RN 1 2 Supply voltage Time limit contact Short time range model 0 1 s to 10 min Long time range model 0 1 min to 10 h 24 VAC 12 24 VDC SPDT H3RN 1 H3RN 11 DPST NO H3RN 2 H3RN 21 Note Specify both the model number and supply vo...

Страница 2: ... H3RN 21 Accuracy of operating time 1 FS max 1 s range 1 10 ms max Setting error 15 50 ms FS max Reset time Min power opening time 12 24 VDC 0 1 s max including halfway reset 24 VAC 0 5 s max including halfway reset Influence of voltage 2 FS max Influence of temperature 2 FS max Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between operating circuit a...

Страница 3: ... level 3 2 kV I O signal line level 4 Immunity Surge IEC51000 4 5 1 kV line to line level 3 2 kV line to ground level 3 Approved standards UL508 CSA C22 2 No 14 Conforms to EN61812 1 IEC60664 1 4 kV 2 Output category according to IEC60947 5 1 Item H3RN 1 H3RN 2 H3RN 11 H3RN 21 OUT PW Bottom View H3RN 1 H3RN 11 H3RN 2 H3RN 21 DIN Indication DIN Indication OUT PW Bottom View Timer circuit Timer circ...

Страница 4: ...t NC 4 2 Time limit contact NO 4 3 Run Power indicator PW Output indicator OUT Power 1 8 Time limit contact NO 4 3 5 6 Run Power indicator PW Output indicator OUT Flicker OFF start Power Output Power 1 5 Time limit contact NC 4 2 Time limit contact NO 4 3 Run Power indicator PW Output indicator OUT Power 1 8 Time limit contact NO 4 3 5 6 Run Power indicator PW Output indicator OUT Flicker ON start...

Страница 5: ...operating modes Nomenclature Model Time range Time setting range Setting Factory set H3RN 1 H3RN 2 1 s 0 1 to 1 s Yes 10 s 1 to 10 s No 1 min 0 1 to 1 min No 10 min 1 to 10 min No H3RN 11 H3RN 21 1 min 0 1 to 1 min Yes 10 min 1 to 10 min No 1 h 0 1 to 1 h No 10 h 1 to 10 h No Operating mode Setting Factory set ON delay Yes Interval No Flicker OFF start No Flicker ON start No Run Power Indicator Gr...

Страница 6: ...se sockets replace with 05 for SPDT or 08 for DPST NO The P2RF cannot be used because the hook is a different shape P2RF E Socket 79 5 see note 1 83 5 see note 2 80 9 see note 1 84 9 see note 2 P2R 7P Socket Note 1 The value shown indicates the dimension for the P2RF 05 E with the PFP N Mounting Rail The value is 71 5 mm when using the PFP N 2 2 The value shown in parentheses indicates the di mens...

Страница 7: ...ed of an SPST NC contact Do not set to the minimum setting in the flicker modes otherwise the contact may be damaged Do not use the H3RN in places where there is excessive dust corro sive gas or direct sunlight Make sure that there is a space of 3 mm or more between any H3RN Models next to each other When using the P2RF E Socket a space of 3 mm or more will be secured If a space of 3 mm or more is...

Страница 8: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L090 E1 02 ...

Отзывы: