H3CR-G
H3CR-G
34
Timing Chart
t1: Star operation time setting
t2: Star-delta transfer time
Model
Timing chart
H3CR-G8L/-G8EL
t1
t2
0.5 s min.
Power (2 – 7)
Instantaneous output
(1 – 3) (-E models)
Star operation
output (8 – 5)
Delta operation
output (8 – 6)
Star operation indicator
Delta operation indicator
ON
OFF
Lit
Not lit
ON
OFF
ON
OFF
ON
OFF
Lit
Not lit