Motor Timer 

H2C

Safety Precautions

Precautions for Safe Use

Observe the following items to ensure the safe use of this product. 

Environmental Precautions

Store the H2C within the specified ratings. If the H2C has been 
stored at temperatures –10

°

C or lower, let it stand for 3 hours or 

longer at room temperature before turning ON the power supply.

Use the H2C within the specified ratings for operating temperature 
and humidity. 

Do not operate the H2C in locations subject to sudden or extreme 
changes in temperature, or locations where high humidity may 
result in condensation. 

Do not use the H2C in locations subject to vibrations or shock. 
Extended use in such locations may result in damage due to stress.

Do not use the H2C in locations subject to excessive dust, 
corrosive gas, or direct sunlight. 

Install the H2C well away from any sources of static electricity, such 
as pipes transporting molding materials, powders, or liquids.

The H2C is not waterproof or oil resistant.
Do not use it in locations subject to water or oil. 

The life expectancy of internal components may be reduced if the 
H2C is mounted side-by-side.

Do not use organic solvents (such as paint thinner or benzine), 
strong alkaline, or strong acids because they will damage the 
external finish. 

Usage Precautions

Install a switch or circuit breaker that allows the operator to 
immediately turn OFF the power, and label it to clearly indicate its 
function. 

Be sure to wire the terminals correctly.

Do not install input lines in the same duct or conduit as power 
supply or other high-voltage lines. Doing so may result in 
malfunction due to noise. Separate the input lines from high-
voltage lines. 

Internal elements may be destroyed if a voltage outside the rated 
voltage is applied. 

Maintain voltage fluctuations in the power supply within the 
specified range. 

Use a switch, relay, or other contact so that the rated power supply 
voltage will be reached within 0.1 s. If the power supply voltage is 
not reached quickly enough, the H2C may malfunction or outputs 
may be unstable. 

Leaving the H2C with outputs ON at a high temperature for a long 
time may hasten the degradation of internal parts (such as 
electrolytic capacitors). Therefore, use the H2C in combination with 
relays and avoid leaving the H2C for more than 1 month with an 
output turned ON.

Precautions for Correct Use

How to Change the Time Range

Change the time range by turning the knob clockwise using a flat-
blade screwdriver or an Allen wrench. There are five possible 
settings. The selected time is displayed in the time range display 
window above the knob.

Do not change the time range while the timer is in operation.

How to Select Power Frequency

Before using the timer, set the frequency selector located at the rear 
panel to the proper power frequency (50 to 60 Hz).

How to Mount the Timer on Mounting 
Track

Mounting

First hook portion A of the timer to the mounting track, then press the 
timer in direction B.

Dismounting

Pull out portion C with a round-blade screwdriver and remove the 
timer from the mounting track.

Electrical Set

The motor and clutch do not need to be reset simultaneously.

Use the voltage applied to the clutch for resetting with the H2C-

@

R. 

Do not allow power to be continuously applied to the motor and 
clutch for extended periods of time.

This may occasionally cause electric shock, fire, or malfunction.
Never disassemble, repair, or modify the H2C.

This may occasionally cause electric shock, fire, or malfunction.
Do not allow metal fragments or lead wire scraps to fall inside the 
H2C.

 

!

CAUTION

X

X

1

T

X

2

X

1

/a

X

2

/b

T/a

X

1

/a

Auxiliary relay 
(e.g., MY Relay)

Time range 
display window

Hex. hole for 
Allen wrench

Groove for flat-
blade screwdriver

50 Hz

60 Hz

B

A

C

Содержание H2C

Страница 1: ... Number Structure Model Number Legend 1 External Connection Attachment None 11 pin socket S 11 pin socket time setting ring 8 8 pin socket F Front screw 2 Operation Resetting System None Time limit operation self resetting R Time limit operation electric resetting Ordering Information List of Models 1 2 H2C Operation resetting system Internal connection Terminal Time limit contact Instantaneous co...

Страница 2: ...pin finger safe type P2CF 08 E 11 pin P2CF 11 11 pin finger safe type P2CF 11 E Back Connecting Socket 8 pin screw terminal P3G 08 8 pin finger safe type P3G 08 with Y92A 48G See note 2 11 pin P3GA 11 11 pin finger safe type P3GA 11 with Y92A 48G See note 2 Hold down Clip See note 3 For PL08 and PL11 Sockets Y92H 1 For PF085A Socket Y92H 2 Time range code Position of time range selector A 1 25 to ...

Страница 3: ...ons min under no load at 1 800 operations h Electrical 500 000 operations min 3 A at 250 VAC resistive load at 1 800 operations h See Life test Curve for other details Motor life expectancy 20 000 h Approved standards UL917 CSA C22 2 No 14 Conforms to EN61812 1 and IEC60664 1 4 kV 1 except for H2C F models Output category according to EN60947 5 1 except for H2C F models EMC except for H2C F models...

Страница 4: ... are for when the clutch is in the excited reset state H2C 8 H2C F H2C S H2C F R H2C SR H2C 8R B2 B1 22 24 A2 21 15 A1 18 16 B2 B1 22 24 A2 21 15 A1 18 16 6 7 8 9 10 11 1 2 3 4 5 B2 B1 22 24 A2 21 15 A1 18 16 6 7 8 9 10 11 1 2 3 4 5 Clutch coil DIN 46 199 5 Clutch coil DIN 46 199 5 ...

Страница 5: ...stantaneous contacts NC 11 21 8 22 Instantaneous contacts NO 11 21 9 24 Timing operation indicator lamp OFF at time up See note Instantaneous contacts NC 11 21 8 22 Instantaneous contacts NO 11 21 9 24 Timing operation indicator lamp OFF at time up See note Power failure time t Rt Resetting time Time limit contacts NC 8 5 Time limit contacts NO 8 6 Time limit contacts NC 1 15 4 16 Time limit conta...

Страница 6: ...current of 1 A max dimension L becomes 10 mm min with an interval of 0 mm between timers For a load current of 3 A max dimension L becomes 15 mm min with an interval of 5 mm between timers For a load current of 6 A max dimension L becomes 20 mm min with an interval of 10 mm between timers Two M4 or 4 5 dia holes 37 dia 100 8 103 1 80 16 3 16 3 85 7 81 5 92 2 H2C 8 H2C 8R These dimensions vary with...

Страница 7: ... 40 0 2 40 0 2 7 8 4 35 4 20 3 19 3 1 3 5 4 5 70 max 50 max 20 3 max P2CF 08 E Finger Safe Terminal Type Conforming to VDE0106 P100 Surface Mounting Holes Two 4 5 dia or two M4 50 max 70 max 21 5 max P2CF 08 Eight M3 5 x 7 5 sems Two 4 5 dia holes Terminal Arrangement Internal Connections Top View Two 4 5 dia holes Eight M3 5 x 7 5 sems ...

Страница 8: ... 2 max P2CF 11 Eleven M3 5 x 7 5 sems Terminal Arrangement Internal Connections Top View Two 4 5 dia holes Two 4 5 dia holes Eleven M3 5 x 7 5 sems 45 45 4 9 17 45 45 25 6 4 5 16 3 6 2 34 47 7 x 47 7 48 x 48 47 4 16 5 24 6 27 6 27 dia P3GA 11 27 dia Finger Safe Terminal Cover Conforming to VDE0106 P100 Y92A 48G Twelve 6 4 dia holes P3G 08 Terminal Arrangement Internal Connections Bottom View Termi...

Страница 9: ...Plate PFP M M4 x 8 pan head screw Spacer PFP S Y92A Y1 Y92A 48B Time Setting Ring Protective Cover The time setting ring locks the time setting knob to store the set time to facilitate its resetting A maximum of two time setting rings are connectable per timer The protective cover shields the front panel particular ly the time setting section from dust dirt and water as well as prevents the set va...

Страница 10: ...ain voltage fluctuations in the power supply within the specified range Use a switch relay or other contact so that the rated power supply voltage will be reached within 0 1 s If the power supply voltage is not reached quickly enough the H2C may malfunction or outputs may be unstable Leaving the H2C with outputs ON at a high temperature for a long time may hasten the degradation of internal parts ...

Страница 11: ...t for H2C F as a built in timer conforms to EN61812 1 provided that the following conditions are satisfied Handling Before dismounting the H2C from the Socket make sure that no voltage is imposed on any terminal of the H2C Applicable Sockets P2CF P2CF E PF085A PL Wiring Basic insulation is ensured between the motor circuit clutch circuit and control output circuit However the H2C 8 motor circuit a...

Страница 12: ...hall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCTS ...

Отзывы: