G7L
G7L
3
Specifications
Coil Ratings
Rated voltage
Rated
current
Coil resistance
Must operate
voltage
Must release
voltage
Max. voltage
Power
consumption
(approx.)
AC (
~
)
12 V
142 mA
---
75% max. of
t d
lt
15% min. of
t d
lt
110% of rated
lt
1.7 to 2.5 VA
(60 H )
( )
24 V
71 mA
---
rated voltage
rated voltage
voltage
(60 Hz)
50 V
34 mA
---
100 to 120 V
17.0 to
20.4 mA
---
75 V
18 V
132 V
200 to 240 V
8.5 to 10.2 mA
---
150 V
36 V
264 v
DC (
=
)
6 V
317 mA
18.9
"
75% max. of
t d
lt
15% min. of
t d
lt
110% of rated
lt
1.9 W
( )
12 V
158 mA
75
"
rated voltage
rated voltage
voltage
24 V
79 mA
303
"
48 V
40 mA
1220
"
100 V
19 mA
5260
"
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
#
C with tolerances of +15%/--20% for AC rated current
and
$
15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23
#
C.
3.
~
indicates AC and
=
indicates DC (IEC417 publications).
Contact Ratings
Model
G7L-1A-T
j
/G7L-1A-B
j
G7L-2A-T
j
/G7L-2A-B
j
G7L-1A-P/G7L-2A-P
Resistive load
(cos
%
= 1)
Inductive load
(cos
%
= 0.4)
Resistive load
(cos
%
= 1)
Inductive load
(cos
%
= 0.4)
Resistive load
(cos
%
= 1)
Inductive load
(cos
%
= 0.4)
Rated load
30 A, 220 VAC
(
~
)
25 A, 220 VAC
(
~
)
25 A, 220 VAC
(
~
)
20 A, 220 VAC
(
~
)
Rated carry
current
30 A
25 A
20 A
Max. switching
voltage
250 VAC
(
~
)
Max. switching
current
30 A
25 A
20 A
Max. switching
power
6,600 VAC
(
~
)
5,500 VAC
(
~
)
5,500 VAC
(
~
)
4,400 VAC
(
~
)
Min. permissible
load*
100 mA, 5 VDC
(
=
)
*Note: P level:
&
60
= 0.1 x 10
-6
/operation