Controlling the Sensor from an External Device
70
FQ Short Manual
If the cycle time is too long, the PLC may not be able to detect when the BUSY signal is ON. If necessary, turn
OFF W0.00 after a suitable time elapses.
Registering the Measurement Reference Again
The model and reference color can be re-registered with commands from an external device, such as a PLC,
based on the image that was just input when the line process was changed.
Settings
[In/Out]
−
[I/O setting]
−
[Input]
−
[Input mode]
Press [Expand mode].
Wiring
Inspection item
Re-registered data
Search
Model data
Color data
Reference color (hue, saturation, and brightness)
Edge Position, Edge Width, Area
None
• Application is possibly only from the Run Mode
• If the parameter is applicable to more than one inspection item, it will be re-registered for all inspection items.
Color
Signal
State
Description
The signals shown at the left are
used.
Refer to the following information for
signal wiring.
2-3 Wiring: p. 15
Gray
IN0
OFF
Command parameter for registering the model
again
Green
IN1
OFF
Red
IN2
OFF
White
IN3
ON
Purple
IN4
OFF
Yellow
IN5
ON
Command input for registering the model again
Orange
OUT1 (BUSY)
--
Processing in progress (default)
Important