Precautions for Correct Use
Installation and Storage Sites (FH-2000/FH-5000 series)
Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to +50°C
*1
(-20 to +65°C in storage)
*1. FH-5000 Series: Surrounding temperature of 0 to 45°C
• No rapid changes in temperature (place where dew does not form)
• Relative humidity of between 35% to 85%
• No presence of corrosive or flammable gases
• Place free of dust, salts and iron particles
• Place free of vibration and shock
• Place out of direct sunlight
• Place where it will not come into contact with water, oils or chemicals
• Place not affected by strong electro-magnetic waves
• Place not near to high-voltage, or high-power equipment
Installation and Storage Sites (FH-L series)
Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to +55°C (-25 to +70°C in storage)
• No rapid changes in temperature (place where dew does not form)
• Relative humidity of between 10 to 90%
• No presence of corrosive or flammable gases
• Place free of dust, salts and iron particles
• Place free of vibration and shock
• Place out of direct sunlight
• Place where it will not come into contact with water, oils or chemicals
• Place not affected by strong electro-magnetic waves
• Place not near to high-voltage, or high-power equipment
Orientation of Product
• For efficient heat dissipation, install the product only with the orientation written in this manual or the
Instruction Sheet. Install the product so that the air can flow freely through its cooling vents.
Ambient Temperature
• To secure good ventilation, install the product with clearance written in this manual or the Instruction
Sheet.
• Do not install the product immediately above significant heat sources, such as heaters, transform-
ers, or large-capacity resistors.
• Use the product within the operating temperature range based on the specifications of it.
• Install a forced cooling fan or air conditioner not to exceed the operating temperature range when
the ambient temperature is close to the upper limit of its range.
Precautions for Correct Use
21
FH Series Vision System Hardware Setup Manual (Z366-E1)
Содержание FH-2 Series
Страница 1: ...Vision Sensor FH Series Vision System Hardware Setup Manual FH 2 FH 2 FH 5 FH 5 FH L FH L Z366 E1 17...
Страница 8: ...Manual Structure 6 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 34: ...Revision History 32 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 48: ...1 Confirm the Package 1 14 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 58: ...2 Overview of FH series 2 10 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 148: ...3 Configuration 3 90 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 154: ...4 Handling and Installation Environment 4 6 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 235: ...I Index I 1 FH Series Vision System Hardware Setup Manual Z366 E1 I...
Страница 242: ...Index I 8 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 243: ......