5-3-3
FH-L Series
Precautions for Safe Use
Power Supply and Wiring
• Keep the power supply wires as short as possible (Max. 2 m).
• Use the wire of a suitable size (AWG 10 to 16) according to the current consumption.
• Recommended power source for FH-L series: OMRON S8VK-G
£££
24 or S8VS-
£££
24.
Ground
• The power supply circuit of the Sensor Controller is not insulated from the internal circuit.
• When a base is packed in a camera that will be connected to the Sensor Controller, make
sure to mount the camera using the base. Since the enclosure of the camera body is con-
nected to the internal circuits, mounting the camera without using the base allows the internal
circuits to be directly connected to the ground, which may cause malfunction or failure.
• Apply Class D grounding (grounding resistance: 100 [Ω] or less)
• Provide the grounding point as close to the product as possible to shorten the grounding wire.
• Wire the grounding wire for the Sensor Controller independently. If the grounding wire is
shared with other devices or connected to a building beam, the Sensor Controller may be
adversely affected.
• Check the wiring again before turning on the power.
Connect the FH-L series Sensor Controller to the FH-MT12 Touch panel monitor.
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and FH-MT12 using a USB cable. The internal circuits may cause a short-circuit and
result in malfunction.
When connect the FH-L series Sensor Controller to the FH-SC12/FH-SM12: 12 megapix-
els camera
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and a 12 megapixels camera like FH-SC12 or FH-SM12.
Other
• There are products in which the enclosure, mounting screw holes, or ground terminal are
short-circuited to 0 V inside (e.g., commercially available monitor products).
Connecting the enclosure, mounting screw holes, or ground terminal of such products to the
Sensor Controller with the ground terminal connected to the ground allows the 0 V reference
inside the product to be directly connected to the ground, which may cause equipment failure
or malfunction.
Connection of Terminal Block of FH-L Series
Connect to the terminal block by using the terminal connector, male: FH-XCN-L, which is packaged
with Sensor Controller.
Use the wire of a suitable size (AWG 12 to 16) according to the current consumption. Keep the power
supply wires as short as possible: Max. 2m.
1
Insert the end of the signal line, electric wire, into the terminal block connector (male). Tighten
the three screws on the connector top to secure the wire. Recommended tightening torque: 0.5
to 0.6 N•m
2
Connect the wire to the terminal block connector (male) depending on the indicated terminal
block connector.
5 Setup and Wiring
5-11
FH Series Vision System Hardware Setup Manual (Z366-E1)
5-3 Sensor Controller Installation
5
5-3-3
FH-L Series
Содержание FH-2 Series
Страница 1: ...Vision Sensor FH Series Vision System Hardware Setup Manual FH 2 FH 2 FH 5 FH 5 FH L FH L Z366 E1 17...
Страница 8: ...Manual Structure 6 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 34: ...Revision History 32 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 48: ...1 Confirm the Package 1 14 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 58: ...2 Overview of FH series 2 10 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 148: ...3 Configuration 3 90 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 154: ...4 Handling and Installation Environment 4 6 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 235: ...I Index I 1 FH Series Vision System Hardware Setup Manual Z366 E1 I...
Страница 242: ...Index I 8 FH Series Vision System Hardware Setup Manual Z366 E1...
Страница 243: ......