F3SJ-A
9
Specifications
(For details, refer to the instruction manual or User's manual.)
F3SJ-A
@@@@
P14/P20/P30/P55/N14/N20/N30/N55
*
Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
Model
PNP Output
F3SJ-A
@@@@
P14
F3SJ-A
@@@@
P20
F3SJ-A
@@@@
P30
F3SJ-A
@@@@
P55
NPN Output
F3SJ-A
@@@@
N14
F3SJ-A
@@@@
N20
F3SJ-A
@@@@
N30
F3SJ-A
@@@@
N55
Sensor type
Type 4 safety light curtain
Version
Ver. 2
Setting tool connection
Connectable
Safety category
Safety purpose of category 4, 3, 2, 1, or B
Detection capability
Opaque objects 14 mm in
diameter
Opaque objects 20 mm in
diameter
Opaque objects 30 mm in
diameter
Opaque objects 55 mm in
diameter
Beam gap (P)
9 mm
15 mm
25 mm
50 mm
Number of beams (n)
26 to 140
16 to 100
10 to 100
6 to 50
Protective height (PH)
245 to 1,271 mm
245 to 1,505 mm
245 to 2,495 mm
270 to 2,470 mm
Lens diameter
Diameter 5 mm
Operating range
*
0.2 to 9 m (protective height 1,640 mm max.),
0.2 to 7 m (protective height 1,655 mm min.)
(Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
Response time
(under stable
light incident
condition)
(For details, see
"Response Time"
on page 76.)
ON to OFF
1 set,
0245 to 983: 11 ms to 17.5 ms max.
1,055 or higher: 20 ms to 25 ms
max.
1 set,
0245 to 1205: 10 ms to 15 ms max.
1235 or higher: 17.5 ms to 22.5 ms
max.
1 set: 10 ms to 17.5 ms
max.
1 set: 10 ms to 13 ms max.
OFF to ON
1 set,
0245 to 983: 44 ms to 70 ms max.
1,055 or higher: 80 ms to 100 ms
max.
1 set,
0245 to 1205: 40 ms to 60 ms max.
1235 or higher: 70 ms to 90 ms
max.
1 set: 40 ms to 70 ms max. 1 set: 40 ms to 52 ms max.
Startup waiting time
2 s max. (2.2 s max. for series connection)
Power supply voltage (Vs)
24 VDC ±20% (ripple p-p10% max.)
Current
consumption
(no load)
Emitter
To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,
151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max.
Receiver
To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,
151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
Light source (emitted wavelength)
Infrared LED (870 nm)
Effective aperture angle (EAA)
Based on IEC 61496-2.Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over
Safety
outputs
(OSSD)
PNP
outputs
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
cable extension),
allowable capacity load 2.2
μ
F, leak current 1 mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
NPN
Output
Two NPN transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
cable extension),
allowable capacity load 2.2
μ
F, leak current 2mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
Auxiliary
output 1
(Non-safety
output)
PNP
outputs
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
cable extension),
leak current 1 mA max.
NPN
output
One NPN transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to
cable extension), leak current 1 mA max.
Auxiliary output 2
(Non-safety
output. Function
for Basic System.)
PNP
outputs
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable
extension),
leak current 1 mA max.
NPN
output
One NPN transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable
extension), leak current 1 mA max.
External indicator output
(Non-safety output)
Available indicators
• Incandescent lamp: 24 VDC, 3 to 7 W
• LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.
(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.)
Output
operation
mode
Receiver
Safety output 1, 2: ON when receiving light
Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.)
External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed
with the setting tool.), ON when muting/override for a muting system (Operation mode
can be changed with the setting tool.)
Emitter
Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed
with the setting tool.)
External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.)
ON when muting/override for a muting system (Operation mode can be changed with
the setting tool.)