7. Operation Check

After setting with DIP Switch, wiring, mounting and beam alignment are done, check the operation of the 
F3SG-RA. Attach the included Troubleshooting Guide Sticker nearby, if necessary.

 

For more information, visit

TROUBLESHOOTING [EN]

http://www.ia.omron.com/f3sg-r

Blinking

OFF

LED INDICATOR

MAJOR CAUSE

LOCKOUT

Blinking Once

TOP

CFG

EDM

INTERNAL

ON/OFF

COM

BTM or LONG

POWER

LOCKOUT

Blinking Twice

POWER

STB

Cap is not attached. Error of other F3SG in cascade.

Error of model combination in cascade

Error of EDM

Error of internal circuit

Error of OSSD lines

Error of communication

Error of DIP-SW setting

Error of emitter

Error due to abnormal power supply or noise

Error due to noise

Error due to vibration or ambient light

ON/OFF, COM, or 

INTERNAL

LOCKOUT

http://www.ia.omron.com/f3sg-r

 Refer to 

Safety Light Curtain F3SG-R Series User's Manual

 or the website for troubleshooting.

Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the 
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable 
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by 
itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, 
machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the 
particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all 
cases. 
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE 
OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

Suitability for Use

In the interest of product improvement, specifications are subject to change without notice.

Regional Headquarters

OMRON EUROPE B.V. (Representative and Importer in EU)
Wegalaan 67-69, NL-2132 JD Hoofddorp
THE NETHERLANDS
Tel: (31)-2356-81-300 / FAX: (31)-2356-81-388

OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900 / Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011 / Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222 / Fax: (86) 21-5037-2200

OMRON Corporation

Industrial Automation Company (Manufacturer)

Contact: www.ia.omron.com

Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN

Suitability for Use

/Contact Information

Mounting/Beam Alignment

Wiring

Setting with DIP Switch

Operation check

Содержание F3SG-4RA****-25-01TS Series

Страница 1: ...F3SG 4RA 25 01TS OMRON Corporation 2016 All Rights Reserved Original instructions http www ia omron com f3sg r...

Страница 2: ...01TS F3SG RA F3SG RA F3SG RA http www ia omron com f3sg r 1 1 2 2 3 2 4 DIP SW 3 5 4 5 1 EDM PNP 4 5 2 EDM 0V NPN 4 6 5 6 1 F39 LGTB F39 LGA 5 6 2 F39 LGA 9 7 12 12 1 LED F3SG 4RA 25 01TS 1 1 1 1 1 D...

Страница 3: ...2 F3SG 4RA 25 01TS 2 3 DIP SW 3 4 5 12...

Страница 4: ...3 F3SG 4RA 25 01TS 4 DIP SW DIP SW 2 DIP SW1 DIP SW2 1 A B 2 EDM EDM EDM 7 PNP NPN PNP NPN 1 A B 2 3 4 24V 0V 1 O N 2 7 1 O N 2 7 1 O N 2 3 4...

Страница 5: ...EDM 0V NPN 2 E1 DC24V F39 JD A L F39 JD A D 0V 3 4 IN1 IN2 1 DIP SW 4 DIP SW 2 b 24V 3 4 F3SG RA DIP SW 1 PNP 24V E1 DC24V S8VS PLC IN E1 DC24V 0V S1 F39 JD A L F39 JD A D DIP SW 4 DIP SW DIP SW NPN...

Страница 6: ...8 2 M5 M6 2 M5 M6 S2 5 N2 35 40 8 G H I 26 5 35 23 2 8 2 A 9 2 72 6 4 84 6 5 N1 2 S3 53 25 F39 LGA F39 LGTB F39 LGTB 2 S3 48 6 35 13 6 4 4 43 D P F F 25 75 24 85 46 5 H 38 5 G 33 75 24 85 72 24 85 72...

Страница 7: ...6 F3SG 4RA 25 01TS F3SG 4RA0185 25 01TS mm 1 F3SG 4RA0185 25 01TS 1 F39 JGR2WTS F39 BT F39 LP F39 BTLP C 185 D 140 G 277 5 H 303 277 5 281 292 5 I 322 303 306 5 318 P 20 2 2...

Страница 8: ...7 F3SG 4RA 25 01TS 1 1 2 S 3 2 F3SG R 1 3 1 3 0N m...

Страница 9: ...8 F3SG 4RA 25 01TS 4 22 5 6 3 0N m...

Страница 10: ...9 F3SG 4RA 25 01TS 6 2 F39 LGA F3SG 4RA 25 01TS A C 23 C 4 D C 45 P 20 C 1 F 0185 1225 2 2 1000mm 1305 1945 3 1000mm mm M5 M6 1 2 0185 0265 1 A 2 1...

Страница 11: ...10 F3SG 4RA 25 01TS 1 2 3 4...

Страница 12: ...11 F3SG 4RA 25 01TS 5 15 6...

Страница 13: ...www ia omron com f3sg r LED 1 TOP CFG EDM INTERNAL ON OFF COM LONG POWER LOCKOUT LOCKOUT 2 POWER LOCKOUT STB http www ia omron com f3sg r Web 0120 919 066 8 00 21 00 365 FAX Web PHS IP 055 982 5015 F...

Страница 14: ...01TS Series OMRON Corporation 2016 All Rights Reserved Original instructions 5132821 8B Quick Installation Manual http www ia omron com f3sg r Document Title Cat No Safty Light Curtain F3SG 4RA 25 01...

Страница 15: ...eam Alignment 5 6 1 Mounted with Top Bottom Adjustable Brackets F39 LGTB and Standard Adjustable Brackets F39 LGA 5 6 2 Mounting with Standard Adjustable Brackets F39 LGA 9 7 Operation Check 12 Suitab...

Страница 16: ...Gray Communication Port Extension cable Emitter Receiver 1 TOP indicator Blue 2 NPN indicator Green 1 Test indicator Green 2 LONG indicator Green 3 Power indicator Green 4 Lockout indicator Red 3 CFG...

Страница 17: ...al Device Monitoring EDM Disabled External Device Monitoring EDM Enabled 7 PNP NPN Selection X PNP NPN Emitter 1 Scan Code X Scan Code A Scan Code B 2 3 Operating Range Selection Short Mode Setting In...

Страница 18: ...share the power supply or be connected to the common terminal of the power supply DIP Switch settings 1 Function Receiver EDM Disabled factory default setting PNP factory default setting Emitter Exte...

Страница 19: ...ither one of emitter and receiver 2 The Top Bottom Adjustable Bracket is not useable together with the Standard Fixed Bracket When it is necessary to use it with another bracket only the combination w...

Страница 20: ...e number of brackets required to mount either one of emitter and receiver Refer to User s Manual for dimensions of side mounting F3SG 4RA0185 25 01TS Optional accessory not connected Optional accessor...

Страница 21: ...the wall are not included Screw 1 Hexagon socket head cap screw M4 10 Top Bottom Bracket 3 Top Bottom Bracket 2 Top Bottom Bracket 1 Top Bottom Bracket 3 Top Bottom Bracket 1 Top Bottom Bracket 2 Scre...

Страница 22: ...tighten the remaining screws Receiver TOP Blue BTM Blue Stable state Green Receiver Receiver Emitter TOP Blue BTM Blue Stable state Green Backside mounting Side mounting The recommended torque to tigh...

Страница 23: ...C 45 Dimension P 20 Protective height C Number of Standard Adjustable Brackets 1 Dimension F 0185 to 1225 2 2 1000 mm max 1305 to 1945 3 1000 mm max Unit mm Screw M5 or M6 Backside mounting 1 The num...

Страница 24: ...ook hexagon socket head cap screw M3 x 15 Backside mounting Side mounting Optical surface of F3SG RA Optical surface of F3SG RA Adjustable Bracket Adjustable Bracket Slide the hook in the groove Slide...

Страница 25: ...table state Green Receiver Receiver Emitter TOP Blue BTM Blue Stable state Green Backside mounting Side mounting Enlarged view Hexagon socket head cap screw M3x15 Tightening torque 2 0 N m recommended...

Страница 26: ...duct in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s...

Отзывы: