F3S-B
19
2-1-3 Distance from Reflective Surfaces
WARNING
Be sure to install the F3S-B to minimize the effects of reflection from reflective surfaces.
Failure to do so will cause detection to fail and may result in serious injury.
Install the F3S-B with minimum Distance D shown below from reflective surfaces (highly reflective sur-
faces) like metal walls, floors, ceilings, and work pieces.
<Side View>
Reflecting ceiling
Emitter
Receiver
Detection zone
L
D
D
Reflecting floor
Emitter
Receiver
L
D
5
°
<Top View>
Reflecting surface
5
°
Distance between emitter and
receiver (detection distance L)
Minimum installation
distance D
0.3 to 3 m
0.27 m
3 to 5 m
L x tan 5° = L x 0.087 (m)
2-1-4 How to Prevent Mutual Interference
Take action to prevent mutual interference when two or more sensors are installed. The following figures
show configurations in which mutual interference may occur.