APPLICATIONS Section
5
5-1 Application (1)
-
without Start/restart interlock function
-
without Relay monitoring function
RS-485(A)
RS-485(B)
O
utput2
Ou
tp
ut
1
Gn
d
Vc
c
Gn
d
Vc
c
KM1
KM2
M
Ext
.
te
st
In
st
ab
ilit
y
Re
lay
m
on
ito
rin
g
E1
S1
KM1 KM2
M: 3-phase motor
E1: 24 VDC Power supply
S1: External test switch
KM1, KM2: Electromagnet contactor (with Reinforced insulation)
Receiver
Emitter
In
ter
loc
k
se
lec
tion
Note:
KM1 and KM2 must have reinforced insula-
tion between the coil and contacts.
5-2 Application (2)
-
with Start/restart interlock function
-
with Relay monitoring function
RS-485(A)
RS-485(B)
O
u
tput2
O
utput1
Gn
d
Vc
c
Gn
d
Vc
c
KM1
KM2
M
E
xt.
tes
t
Ins
tabi
lity
Re
lay
mo
nit
or
ing
E1
S1
S2
KM1 KM2
M: 3-phase motor
E1: 24 VDC Power supply
S1: External test switch
S2: Restart interlock reset switch
KM1, KM2: Electromagnet contactor (with Reinforced insulation)
Receiver
Emitter
Inter
loc
k
sel
ec
tion
Note:
KM1 and KM2 must have reinforced insula-
tion between the coil and contacts as well as
between contacts.