The remote or manual automatic teaching of the F3M-S825-1 is

possible with the following two sensitivity settings:
1. Max. Sensitivity Setting: Detects semiconductor silicon

wafers, and SIC wafers.

2. Teaching with No Target Object: Detects transparent wafers.
The sensitivity is set to maximum before shipping. Refer to the

Instruction Manual when setting the sensitivity of the F3M-S825-1.

Power indicator

Warning indicator

Teaching button

RUN/TEACH mode selector Teaching indicator

J

AUTOMATIC TEACHING FUNCTION

F3M-S825-1

The F3M-S825-1 has an answer-back function to warn the

user about setting errors and a self-diagnostic function to

warn the user about operational errors.

x

Answer-back Function: Normal or error teaching output

turns ON.

x

Self-diagnostic Function: Warning output turns ON for a

decrease in optical input.

J

ANSWER-BACK FUNCTION AND

SELF-DIAGNOSTIC FUNCTION

Operation

J

OUTPUT CIRCUIT DIAGRAM

+V

Output

(OUT1)

Output (see note)

(OUT26)

0 V

Mai

n

ci

rc

ui

t

Control output interrupt input

Remote teaching input

J

I/O TERMINAL ARRANGEMENT

Pin assignment

Pin Assignment

Pin

Assignment

1

GND (0 V)

16

OUT14

2

V

CC

(12 to 24 V)

17

OUT15

3

OUT1

18

OUT16

4

OUT2

19

OUT17

5

OUT3

20

OUT18

6

OUT4

21

OUT19

7

OUT5

22

OUT20

8

OUT6

23

OUT21

9

OUT7

24

OUT22

10

OUT8

25

OUT23

11

OUT9

26

OUT24

12

OUT10

27

OUT25

13

OUT11

28

Self-diagnostic output/OUT26

(See Note.)

14

OUT12

29

Control output interrupt input

15

OUT13

30

Remote teaching input

Note: Pin 28 will have answer-back output only when remote

teaching input is turned ON. Otherwise, this output is a

self-diagnostic output.

Отзывы: