F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL

   7

7-1 Ratings...........................................................................7-2

Technical specifications

Содержание F3EM2 Series

Страница 1: ...01 Measuring Light Curtain OPERATION MANUAL Cat No E77E EN 01 Note Specifications subject to change without notice Authorized Distributor Printed in Europe Cat No E77E EN 01 F3EM2 Measuring Light Curt...

Страница 2: ...Manufacturer OMRON Europe B V Wegalaan 67 69 2132 JD Hoofddorp THE NETHERLANDS WWW www industrial omron eu User s Manual Version 0 2 dated 18 10 2011...

Страница 3: ...ht curtain in locations with explosive or flammable gas Make sure that the product is operated in accordance with IP65 standards Do not subject the light curtain to excessive shock when mounting When...

Страница 4: ......

Страница 5: ...Operation Analog models 4 1 DIP switch setting 4 2 4 2 Analog output value 4 3 Chapter 5 Operating serial output models RS 232C 5 1 DIP switch setting Overview 5 2 5 2 Transmission speed baud rate 5...

Страница 6: ...4...

Страница 7: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 1 1 1 Applications 1 2 1 2 Model line up 1 3 Overview...

Страница 8: ...esigned for easy height and profile measurement for various applications Programming via dip switches makes it easy to set up F3EM2 everywhere without external controller or Remote PC Due to its robus...

Страница 9: ...V RS485 analogue 0 10 V on request F3EM2 is available in two resolutions Models with 7 5mm resolution are available upon request Due to its modular design F3EM2 can be provided in various sizes For s...

Страница 10: ......

Страница 11: ...2 3 Mounting accessories 2 3 Additional mounting rigidity 2 3 Mechanical Mounting 2 4 2 3 Operating environment 2 4 2 4 Operating distances 2 4 Analogue models 2 5 Models with serial analogue output...

Страница 12: ...he upper beam located on the opposite side of the connector see illustration below During operation this beam must always be kept free Otherwise it will result a loss of synchronism between the transm...

Страница 13: ...wers and nuts to fix the mounting brackets as shown in the picture Note Shipment contains different quantity of brackets depending on the length of the SLC Longer SLC contains a higher number of brack...

Страница 14: ...ating environment The area for the installation of the light curtain must be suitable according to the technical specifications The temperature of the environment interference caused by electromagneti...

Страница 15: ...white wires of transmitter and receiver Variable Power Supply RECEIVER F3EM2 analogue out only EMITTER F3EM2 Br Wh Bl Bk Br Wh Bl Bk Analogue Gr Earth Ground 24 VDC 0 VDC Connector PIN assignment Rec...

Страница 16: ...h its own internal self resetting fuse Variable Power Supply RECEIVER F3EM2 Earth Ground 24 VDC 0 VDC Wh Br Gn Ye Gr Pk Bl Rd Analogue RS out EMITTER F3EM2 SYNC Br Wh Bl Bk S1 Connector PIN assignment...

Страница 17: ...de baud rate and distance can be changed by selector switches To access the selector switches unscrew the end cap of the receiver and transmitter unit There are two lines of dip switches in each trans...

Страница 18: ......

Страница 19: ...N MANUAL 3 F3EM2 is not a safety device The usage of F3EM2 as Safety protection equipment is dangerous and prohibited and expose personnel to serious injury 3 1 Beam order 3 2 3 2 Output modes 3 3 Ope...

Страница 20: ...eceiver The status of each beam open or blocked is controlled every scan cycle and the output reflects the current status accordingly Thus size and position of objects can be detected Different output...

Страница 21: ...ked First beam in chain obscured by object FBM First Beam Made First beam in chain that is open NBB Number of Beams Blocked Total number of blocked beams no holes included NAB Number of Area Blocked N...

Страница 22: ......

Страница 23: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 4 4 1 DIP switch setting 4 2 4 2 Analog output value 4 3 Operation Analog models...

Страница 24: ...for both lines Dip SW Status Function 1 OFF Optical Sync default ON Wire sync 2 Not used 3 4 3 4 Output signal OFF OFF NAB default OFF ON LBB ON OFF NBB ON ON FBB 5 OFF FAR default ON NEAR 6 Not used...

Страница 25: ...ationship to the number of interrupted beams NBB or NBM setting or to the position index of beam FBB or LBB Example for NAB setting Example for FBB setting The analogue output is refreshed every scann...

Страница 26: ......

Страница 27: ...d baud rate 5 4 5 3 Beam aquisition and data aquisition 5 4 5 4 Communication protocol for serial output 5 5 Bitmap of optics 5 5 FBB NBB 5 6 FBM NAB 5 6 LBB NBB 5 7 LBM NBM 5 7 Continues bitmap trans...

Страница 28: ...switch setting transmitter Dip SW Status Function 1 OFF Optical Synch default ON Wire synch 2 3 RS baud rate 2 3 Speed OFF OFF 9600bps default OFF ON 19200bps ON OFF 38400bps ON ON 76800bps 4 Not used...

Страница 29: ...N OFF 38400bps ON ON 76800bps 4 5 Interrogation byte for serial operation 4 5 Hexadecimal code binary code Analogue output OFF OFF FAh 11111010 default 0 10V default OFF ON FBh 11111011 0 10V ON OFF F...

Страница 30: ...ams and the previous one See an example of a data acquisition resulting from two beam acquisitions Triggered by an interrogation code the light curtain sends the acquired data and cleans the beam stat...

Страница 31: ...can be used also as a check for the correctness of the serial wiring and or communication protocol The different operation modes are described below Bitmap of optics Dip switch setting The light curt...

Страница 32: ...protocol of a light curtain with 9 beams and FBB NBB settings FBB 4 NBB 4 HEX FORMAT H high order byte L low order byte FBM NAB Dip switch setting The reply received from the light curtain is composed...

Страница 33: ...n of the LBM id number NAB data is the binary conversion of the NAB number The order of bytes in the protocol is same as example described for FBB NBB setting Continues bitmap transmission Dip switch...

Страница 34: ...ap of optics on page 5 5 Holes detection function Dip switch setting This function transmits the bitmap of beams with inverted bit signals The default setting 0 beam free and 1 beam broken is converte...

Страница 35: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 6 Order codes...

Страница 36: ...3EM2 005 600 AV 600 5 mm 3 m 120 F3EM2 018 600 F3EM2 018 600 AV 18 mm 15 m 32 F3EM2 005 900 F3EM2 005 900 AV 900 5 mm 3 m 180 F3EM2 018 900 F3EM2 018 900 AV 18 mm 15 m 48 F3EM2 005 1200 F3EM2 005 1200...

Страница 37: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 7 7 1 Ratings 7 2 Technical specifications...

Страница 38: ...DC 20 Current consumption 150 mA max excluded load on digital Power on delay 1 s Response time 4 ms 80 s x number of beams transmitting time for serial operation 1 Outputs RS 232C RS485 Analogue 0 10...

Страница 39: ...MEASURING LIGHT CURTAINS OPERATION MANUAL 8 8 1 LED indication on receiver unit 8 2 8 2 LED indication on emitter unit 8 3 8 3 Troubleshooting for error indication 8 4 LED indicators and error indica...

Страница 40: ...on on receiver SYMBOL MEANING Diagnosis LED off Diagnosis LED on Diagnosis LED blinking Disposition of indicator Name of indicator Colour POWER Green RUN Yellow FREE Green BREAK Red STATUS Yellow POWE...

Страница 41: ...itter LED error indication on emitter Disposition of indicator Name of indicator Colour POWER Green STATUS 1 Yellow RANGE Green Not used Red STATUS 2 Yellow POWER STATUS 1 RANGE STATUS 2 TX LED signal...

Страница 42: ...Check if power supply is within specification of 24Vdc 20 2 Turn the unit ON and OFF again If the error persist please contact manufacturer 3 Turn the unit ON and OFF again If the error persist please...

Страница 43: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 9 Dimensions...

Страница 44: ...EM2 005 450 AV 477 536 F3EM2 018 450 AV 441 511 F3EM2 005 600 AV 636 695 F3EM2 018 600 AV 588 658 F3EM2 005 900 AV 954 1013 F3EM2 018 900 AV 882 952 F3EM2 005 1200 AV 1272 1331 F3EM2 018 1200 AV 1176...

Страница 45: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 10 10 1 Mounting bracket 10 2 10 2 Cables 10 2 Accessories...

Страница 46: ...10 2 Cables For other accessories like alignment kit special brackets or connector cables please contact your sales representative Order Code Length M12 8pin straight shielded Y92E M12PURSH8S2M L 2 m...

Страница 47: ...manual revision symbol is an alphabet appended at the end of the manual number found in the bottom left hand corner of the front or back cover Example Revision symbol Revision date Description of rev...